I just got a Fibaro CO sensor which is supported by OpenZWave. In the MozillaIoT gateway, it is not recognized as a CO sensor but as a "thing" which displays the temperature and battery life correctly but unfortunately not the CO level.
I looked through the log files and it is apparently able to read the CO value (I think) but it does not show in the gui. I see this no property found message on all properties (including the temperature and battery which are correctly displayed in the graphical interface).
2019-06-29 19:21:44.242 INFO : zwave: node4 valueChanged: 4-49-1-1:Temperature = 27.5 C (no property found)
2019-06-29 19:21:44.278 INFO : zwave: node4 valueChanged: 4-49-1-1:Temperature = 27.5 C (no property found)
2019-06-29 19:21:44.353 INFO : zwave: node4 valueChanged: 4-128-1-0:Battery Level = 100 % (no property found)
2019-06-29 19:21:44.390 INFO : zwave: node4 valueChanged: 4-156-1-0:General = 0 (no property found)
2019-06-29 19:21:44.428 INFO : zwave: node4 valueChanged: 4-156-1-2:Carbon Monoxide = 0 (no property found)
2019-06-29 19:21:44.465 INFO : zwave: node4 valueChanged: 4-156-1-4:Heat = 0 (no property found)
The other thing is that this device can send alerts! If the CO or temperature exceeds a threshold, it can send an alert message.
I found the table specifying how the CO should be modeled on zwave:
CO Alarm 0x02 State (Refer to parameters) N/A State idle 0x00 V4 Notification value for the state variable going to idle. (V5)
State Sensor status Idle Carbon monoxide detected (location provided) 0x01 V2 Node Location Report (Node Naming and Location Command Class)
State Sensor status Idle Carbon monoxide detected 0x02 V2
State Test status N/A Carbon monoxide test 0x03 V5 0x01 = Test OK 0x02 = Test Failed The Carbon monoxide Test event may be issued by an alarm device to advertise that the test mode of the device has been activated. The activation may be manual or via signaling. A receiving application SHOULD NOT activate any alarms in response to this event.
State Maintenance status Idle Replacement required 0x04 V5 This event may be issued by an alarm device to advertise that its physical components are no more reliable, e.g. because of clogged filters.
State Maintenance status Idle Replacement required, End-of-life 0x05 V8
State Alarm status Idle Alarm silenced 0x06 V8
State Periodic inspection status Idle Maintenance required, planned periodic inspection 0x07 V8
N/A N/A N/A Unknown event/state 0xFE V2
thanks!
Sam
The full log is here:
2019-06-29 19:20:54.517 INFO : zwave: ===============================================
2019-06-29 19:20:54.520 INFO : zwave: Press the inclusion button on the ZWave device to add
2019-06-29 19:20:54.522 INFO : zwave: ===============================================
2019-06-29 19:20:54.524 INFO : zwave: Sending pairing prompt
2019-06-29 19:20:54.526 INFO : zwave: Controller Command feedback: AddDevice ControllerCommand - Starting node0 retVal:1 state:0
2019-06-29 19:20:54.527 INFO : zwave: Controller Command feedback: AddDevice ControllerCommand - Waiting node0 retVal:4 state:0
2019-06-29 19:20:54.614 INFO : Opened a new things socket
2019-06-29 19:21:19.196 INFO : zwave: Controller Command feedback: AddDevice ControllerCommand - InProgress node0 retVal:6 state:0
2019-06-29 19:21:19.376 INFO : zwave: Controller Command feedback: AddDevice ControllerCommand - InProgress node0 retVal:6 state:0
2019-06-29 19:21:19.702 INFO : zwave: Controller Command feedback: AddDevice ControllerCommand - InProgress node0 retVal:6 state:0
2019-06-29 19:21:19.761 INFO : zwave: node4 valueAdded: 4-128-1-0:Battery Level = 100 %
2019-06-29 19:21:19.762 INFO : zwave: Controller Command feedback: AddDevice ControllerCommand - Completed node0 retVal:7 state:0
2019-06-29 19:21:19.831 INFO : zwave: node4 valueChanged: 4-132-1-0:Wake-up Interval = 21600 Seconds (no property found)
2019-06-29 19:21:19.901 INFO : zwave: node4 valueChanged: 4-114-1-1:Config File Revision = 1 (no property found)
2019-06-29 19:21:19.903 INFO : zwave: node4 valueChanged: 4-114-1-0:Loaded Config Revision = 1 (no property found)
2019-06-29 19:21:19.910 INFO : zwave: node4: Named FIBARO System FGSD001 CO Sensor
2019-06-29 19:21:19.912 INFO : zwave: node4: name="zwave-f2e7f3a6-4-Battery Level", type="Notification Sensor", location=""
2019-06-29 19:21:19.949 INFO : zwave: node4 valueAdded: 4-48-1-0:Sensor = false
2019-06-29 19:21:19.951 INFO : zwave: node4 valueChanged: 4-94-1-0:ZWave+ Version = 1 (no property found)
2019-06-29 19:21:19.952 INFO : zwave: node4 valueChanged: 4-94-1-1:InstallerIcon = 3074 (no property found)
2019-06-29 19:21:19.954 INFO : zwave: node4 valueChanged: 4-94-1-2:UserIcon = 3074 (no property found)
2019-06-29 19:21:20.145 INFO : zwave: node4 valueAdded: 4-49-1-1:Temperature = 0.0
2019-06-29 19:21:20.147 INFO : zwave: node4 valueAdded: 4-49-1-40:CO Level = 0.0
2019-06-29 19:21:20.183 INFO : zwave: node4 valueChanged: 4-94-1-0:ZWave+ Version = 1 (no property found)
2019-06-29 19:21:20.185 INFO : zwave: node4 valueChanged: 4-94-1-1:InstallerIcon = 3074 (no property found)
2019-06-29 19:21:20.186 INFO : zwave: node4 valueChanged: 4-94-1-2:UserIcon = 3074 (no property found)
2019-06-29 19:21:20.258 INFO : zwave: node4 valueAdded: 4-113-1-256:Previous Event Cleared = 0
2019-06-29 19:21:20.265 INFO : zwave: node4 valueAdded: 4-113-1-258:Result = Test
2019-06-29 19:21:20.267 INFO : zwave: node4 valueAdded: 4-113-1-2:Carbon Monoxied = Clear
2019-06-29 19:21:20.297 INFO : zwave: node4 valueAdded: 4-113-1-4:Heat = Clear
2019-06-29 19:21:20.334 INFO : zwave: node4 valueAdded: 4-113-1-7:Home Security = Clear
2019-06-29 19:21:20.372 INFO : zwave: node4 valueAdded: 4-113-1-8:Power Management = Clear
2019-06-29 19:21:20.409 INFO : zwave: node4 valueAdded: 4-113-1-9:System = Clear
2019-06-29 19:21:20.449 INFO : zwave: node4 valueChanged: 4-114-1-4:Serial Number = 000000000000xxxx (no property found)
2019-06-29 19:21:20.488 INFO : zwave: node4 valueChanged: 4-114-1-4:Serial Number = 000000000000xxxx (no property found)
2019-06-29 19:21:20.526 INFO : zwave: node4 valueChanged: 4-132-1-1:Minimum Wake-up Interval = 0 Seconds (no property found)
2019-06-29 19:21:20.529 INFO : zwave: node4 valueChanged: 4-132-1-2:Maximum Wake-up Interval = 43200 Seconds (no property found)
2019-06-29 19:21:20.530 INFO : zwave: node4 valueChanged: 4-132-1-3:Default Wake-up Interval = 21600 Seconds (no property found)
2019-06-29 19:21:20.531 INFO : zwave: node4 valueChanged: 4-132-1-4:Wake-up Interval Step = 3600 Seconds (no property found)
2019-06-29 19:21:20.602 INFO : zwave: node4 valueChanged: 4-134-1-0:Library Version = 3 (no property found)
2019-06-29 19:21:20.604 INFO : zwave: node4 valueChanged: 4-134-1-1:Protocol Version = 4.38 (no property found)
2019-06-29 19:21:20.606 INFO : zwave: node4 valueChanged: 4-134-1-2:Application Version = 3.02 (no property found)
2019-06-29 19:21:20.676 INFO : zwave: node4 valueAdded: 4-156-1-0:General = 0
2019-06-29 19:21:20.679 INFO : zwave: node4 valueAdded: 4-156-1-2:Carbon Monoxide = 0
2019-06-29 19:21:20.680 INFO : zwave: node4 valueAdded: 4-156-1-4:Heat = 0
2019-06-29 19:21:21.014 INFO : zwave: Controller Command feedback: DeleteAllReturnRoutes ControllerCommand - Starting node0 retVal:1 state:0
2019-06-29 19:21:21.022 INFO : zwave: Controller Command feedback: DeleteAllReturnRoutes ControllerCommand - InProgress node0 retVal:6 state:0
2019-06-29 19:21:21.204 INFO : zwave: Controller Command feedback: DeleteAllReturnRoutes ControllerCommand - Completed node0 retVal:7 state:0
2019-06-29 19:21:21.206 INFO : zwave: Controller Command feedback: AssignReturnRoute ControllerCommand - Starting node0 retVal:1 state:0
2019-06-29 19:21:21.215 INFO : zwave: Controller Command feedback: AssignReturnRoute ControllerCommand - InProgress node0 retVal:6 state:0
2019-06-29 19:21:21.650 INFO : zwave: node4 valueChanged: 4-114-1-2:Latest Available Config File Revision = 5 (no property found)
2019-06-29 19:21:21.651 ERROR : zwave: Unhandled OpenZWave notification: 30
2019-06-29 19:21:21.772 INFO : zwave: Controller Command feedback: AssignReturnRoute ControllerCommand - Completed node0 retVal:7 state:0
2019-06-29 19:21:21.815 INFO : zwave: node4 valueChanged: 4-115-1-0:Powerlevel = Normal dB (no property found)
2019-06-29 19:21:21.817 INFO : zwave: node4 valueChanged: 4-115-1-1:Timeout = 0 seconds (no property found)
2019-06-29 19:21:21.853 INFO : zwave: node4 valueChanged: 4-132-1-0:Wake-up Interval = 21600 Seconds (no property found)
2019-06-29 19:21:22.104 INFO : zwave: node4 valueRemoved: 4-32-1-0:Basic = 0
2019-06-29 19:21:22.107 INFO : zwave: node4 valueRemoved: 4-48-1-0:Sensor = false
2019-06-29 19:21:22.109 INFO : zwave: node4 valueRemoved: 4-94-1-0:ZWave+ Version = 1
2019-06-29 19:21:22.110 INFO : zwave: node4 valueRemoved: 4-114-1-0:Loaded Config Revision = 1
2019-06-29 19:21:22.112 INFO : zwave: node4 valueRemoved: 4-115-1-0:Powerlevel = Normal dB
2019-06-29 19:21:22.114 INFO : zwave: node4 valueRemoved: 4-128-1-0:Battery Level = 100 %
2019-06-29 19:21:22.117 INFO : zwave: node4 valueRemoved: 4-132-1-0:Wake-up Interval = 21600 Seconds
2019-06-29 19:21:22.119 INFO : zwave: node4 valueRemoved: 4-134-1-0:Library Version = 3
2019-06-29 19:21:22.121 INFO : zwave: node4 valueRemoved: 4-156-1-0:General = 0
2019-06-29 19:21:22.123 INFO : zwave: node4 valueRemoved: 4-49-1-1:Temperature = 0.0
2019-06-29 19:21:22.125 INFO : zwave: node4 valueRemoved: 4-94-1-1:InstallerIcon = 3074
2019-06-29 19:21:22.126 INFO : zwave: node4 valueRemoved: 4-114-1-1:Config File Revision = 1
2019-06-29 19:21:22.128 INFO : zwave: node4 valueRemoved: 4-115-1-1:Timeout = 0 seconds
2019-06-29 19:21:22.130 INFO : zwave: node4 valueRemoved: 4-132-1-1:Minimum Wake-up Interval = 0 Seconds
2019-06-29 19:21:22.131 INFO : zwave: node4 valueRemoved: 4-134-1-1:Protocol Version = 4.38
2019-06-29 19:21:22.132 INFO : zwave: node4 valueRemoved: 4-94-1-2:UserIcon = 3074
2019-06-29 19:21:22.133 INFO : zwave: node4 valueRemoved: 4-112-1-2:Z-Wave notifications = All notifications disabled
2019-06-29 19:21:22.135 INFO : zwave: node4 valueRemoved: 4-113-1-2:Carbon Monoxied = Clear
2019-06-29 19:21:22.136 INFO : zwave: node4 valueRemoved: 4-114-1-2:Latest Available Config File Revision = 5
2019-06-29 19:21:22.138 INFO : zwave: node4 valueRemoved: 4-115-1-2:Set Powerlevel = undefined
2019-06-29 19:21:22.139 INFO : zwave: node4 valueRemoved: 4-132-1-2:Maximum Wake-up Interval = 43200 Seconds
2019-06-29 19:21:22.140 INFO : zwave: node4 valueRemoved: 4-134-1-2:Application Version = 3.02
2019-06-29 19:21:22.142 INFO : zwave: node4 valueRemoved: 4-156-1-2:Carbon Monoxide = 0
2019-06-29 19:21:22.143 INFO : zwave: node4 valueRemoved: 4-112-1-3:LED diode indications = 0
2019-06-29 19:21:22.144 INFO : zwave: node4 valueRemoved: 4-114-1-3:Device ID =
2019-06-29 19:21:22.145 INFO : zwave: node4 valueRemoved: 4-115-1-3:Test Node = 0
2019-06-29 19:21:22.147 INFO : zwave: node4 valueRemoved: 4-132-1-3:Default Wake-up Interval = 21600 Seconds
2019-06-29 19:21:22.148 INFO : zwave: node4 valueRemoved: 4-112-1-4:Acoustic signals = 0
2019-06-29 19:21:22.150 INFO : zwave: node4 valueRemoved: 4-113-1-4:Heat = Clear
2019-06-29 19:21:22.151 INFO : zwave: node4 valueRemoved: 4-114-1-4:Serial Number = 000000000000xxxx
2019-06-29 19:21:22.153 INFO : zwave: node4 valueRemoved: 4-115-1-4:Test Powerlevel = Normal dB
2019-06-29 19:21:22.155 INFO : zwave: node4 valueRemoved: 4-132-1-4:Wake-up Interval Step = 3600 Seconds
2019-06-29 19:21:22.156 INFO : zwave: node4 valueRemoved: 4-156-1-4:Heat = 0
2019-06-29 19:21:22.157 INFO : zwave: node4 valueRemoved: 4-115-1-5:Frame Count = 0
2019-06-29 19:21:22.159 INFO : zwave: node4 valueRemoved: 4-115-1-6:Test = undefined
2019-06-29 19:21:22.160 INFO : zwave: node4 valueRemoved: 4-112-1-7:Associations in Z-Wave network security mode = 63
2019-06-29 19:21:22.162 INFO : zwave: node4 valueRemoved: 4-113-1-7:Home Security = Clear
2019-06-29 19:21:22.163 INFO : zwave: node4 valueRemoved: 4-115-1-7:Report = undefined
2019-06-29 19:21:22.164 INFO : zwave: node4 valueRemoved: 4-113-1-8:Power Management = Clear
2019-06-29 19:21:22.166 INFO : zwave: node4 valueRemoved: 4-115-1-8:Test Status = Failed
2019-06-29 19:21:22.167 INFO : zwave: node4 valueRemoved: 4-113-1-9:System = Clear
2019-06-29 19:21:22.169 INFO : zwave: node4 valueRemoved: 4-115-1-9:Acked Frames = 0
2019-06-29 19:21:22.170 INFO : zwave: node4 valueRemoved: 4-112-1-10:Commands sent to 2nd association group (CO Alarm) = BASIC ON and OFF
2019-06-29 19:21:22.171 INFO : zwave: node4 valueRemoved: 4-112-1-11:Value of BASIC ON command sent to 2nd association group = 255
2019-06-29 19:21:22.173 INFO : zwave: node4 valueRemoved: 4-112-1-12:Value of BASIC OFF command sent to 2nd association group = 0
2019-06-29 19:21:22.174 INFO : zwave: node4 valueRemoved: 4-112-1-13: Commands sent to 4th association group (CO Level) = BASIC ON and OFF
2019-06-29 19:21:22.176 INFO : zwave: node4 valueRemoved: 4-112-1-14:CO level required for sending BASIC ON command to 4th association group = 40 ppm
2019-06-29 19:21:22.177 INFO : zwave: node4 valueRemoved: 4-112-1-15:Time required for sending BASIC ON command to 4th association group = 0
2019-06-29 19:21:22.179 INFO : zwave: node4 valueRemoved: 4-112-1-16:Value of BASIC ON command sent to 4th association group = 255
2019-06-29 19:21:22.180 INFO : zwave: node4 valueRemoved: 4-112-1-17:CO Level required for sending BASIC OFF command to 4th association group = 25 ppm
2019-06-29 19:21:22.181 INFO : zwave: node4 valueRemoved: 4-112-1-18:Time required for sending BASIC OFF command to 4th association group = 0
2019-06-29 19:21:22.182 INFO : zwave: node4 valueRemoved: 4-112-1-19:Value of BASIC OFF command sent to 4th association group = 0
2019-06-29 19:21:22.184 INFO : zwave: node4 valueRemoved: 4-112-1-20:Temperature report interval = 0
2019-06-29 19:21:22.185 INFO : zwave: node4 valueRemoved: 4-112-1-21:Temperature report hysteresis = 2
2019-06-29 19:21:22.187 INFO : zwave: node4 valueRemoved: 4-112-1-22:Threshold of exceeding the temperature = 55 Celsius
2019-06-29 19:21:22.189 INFO : zwave: node4 valueRemoved: 4-112-1-23:CO meter activation = 1
2019-06-29 19:21:22.190 INFO : zwave: node4 valueRemoved: 4-112-1-25: CO level reporting hysteresis = 10 ppm
2019-06-29 19:21:22.192 INFO : zwave: node4 valueRemoved: 4-112-1-26:Threshold of CO meter activation = 30 ppm
2019-06-29 19:21:22.193 INFO : zwave: node4 valueRemoved: 4-49-1-40:CO Level = 0.0
2019-06-29 19:21:22.194 INFO : zwave: node4 valueRemoved: 4-113-1-256:Previous Event Cleared = 0
2019-06-29 19:21:22.198 INFO : zwave: node4 valueRemoved: 4-113-1-258:Result = Test
2019-06-29 19:21:22.200 INFO : zwave: node4 valueChanged: 4-132-1-0:Wake-up Interval = 21600 Seconds (no property found)
2019-06-29 19:21:22.233 INFO : zwave: node4 valueChanged: 4-114-1-1:Config File Revision = 5 (no property found)
2019-06-29 19:21:22.236 INFO : zwave: node4 valueChanged: 4-114-1-0:Loaded Config Revision = 5 (no property found)
2019-06-29 19:21:22.239 INFO : zwave: node4: Named FIBARO System FGSD001 CO Sensor
2019-06-29 19:21:22.241 INFO : zwave: node4: name="zwave-f2e7f3a6-4", type="Notification Sensor", location=""
2019-06-29 19:21:22.265 INFO : zwave: node4 valueChanged: 4-114-1-2:Latest Available Config File Revision = 5 (no property found)
2019-06-29 19:21:22.283 INFO : zwave: node4 valueAdded: 4-128-1-0:Battery Level = 100 %
2019-06-29 19:21:22.324 INFO : zwave: node4 valueAdded: 4-48-1-0:Sensor = false
2019-06-29 19:21:22.326 INFO : zwave: node4 valueChanged: 4-94-1-0:ZWave+ Version = 1 (no property found)
2019-06-29 19:21:22.327 INFO : zwave: node4 valueChanged: 4-94-1-1:InstallerIcon = 3074 (no property found)
2019-06-29 19:21:22.329 INFO : zwave: node4 valueChanged: 4-94-1-2:UserIcon = 3074 (no property found)
2019-06-29 19:21:22.516 INFO : zwave: node4 valueAdded: 4-49-1-1:Temperature = 0.0
2019-06-29 19:21:22.518 INFO : zwave: node4 valueAdded: 4-49-1-40:CO Level = 0.0
2019-06-29 19:21:22.558 INFO : zwave: node4 valueChanged: 4-94-1-0:ZWave+ Version = 1 (no property found)
2019-06-29 19:21:22.560 INFO : zwave: node4 valueChanged: 4-94-1-1:InstallerIcon = 3074 (no property found)
2019-06-29 19:21:22.562 INFO : zwave: node4 valueChanged: 4-94-1-2:UserIcon = 3074 (no property found)
2019-06-29 19:21:22.633 INFO : zwave: node4 valueAdded: 4-113-1-256:Previous Event Cleared = 0
2019-06-29 19:21:22.636 INFO : zwave: node4 valueAdded: 4-113-1-258:Result = Test
2019-06-29 19:21:22.637 INFO : zwave: node4 valueAdded: 4-113-1-2:Carbon Monoxied = Clear
2019-06-29 19:21:22.671 INFO : zwave: node4 valueAdded: 4-113-1-4:Heat = Clear
2019-06-29 19:21:22.708 INFO : zwave: node4 valueAdded: 4-113-1-7:Home Security = Clear
2019-06-29 19:21:22.746 INFO : zwave: node4 valueAdded: 4-113-1-8:Power Management = Clear
2019-06-29 19:21:22.784 INFO : zwave: node4 valueAdded: 4-113-1-9:System = Clear
2019-06-29 19:21:22.823 INFO : zwave: node4 valueChanged: 4-114-1-4:Serial Number = 000000000000xxxx (no property found)
2019-06-29 19:21:22.862 INFO : zwave: node4 valueChanged: 4-114-1-4:Serial Number = 000000000000xxxx (no property found)
2019-06-29 19:21:22.901 INFO : zwave: node4 valueChanged: 4-132-1-1:Minimum Wake-up Interval = 0 Seconds (no property found)
2019-06-29 19:21:22.903 INFO : zwave: node4 valueChanged: 4-132-1-2:Maximum Wake-up Interval = 43200 Seconds (no property found)
2019-06-29 19:21:22.904 INFO : zwave: node4 valueChanged: 4-132-1-3:Default Wake-up Interval = 21600 Seconds (no property found)
2019-06-29 19:21:22.906 INFO : zwave: node4 valueChanged: 4-132-1-4:Wake-up Interval Step = 3600 Seconds (no property found)
2019-06-29 19:21:22.976 INFO : zwave: node4 valueChanged: 4-134-1-0:Library Version = 3 (no property found)
2019-06-29 19:21:22.980 INFO : zwave: node4 valueChanged: 4-134-1-1:Protocol Version = 4.38 (no property found)
2019-06-29 19:21:22.981 INFO : zwave: node4 valueChanged: 4-134-1-2:Application Version = 3.02 (no property found)
2019-06-29 19:21:23.052 INFO : zwave: node4 valueAdded: 4-156-1-0:General = 0
2019-06-29 19:21:23.054 INFO : zwave: node4 valueAdded: 4-156-1-2:Carbon Monoxide = 0
2019-06-29 19:21:23.056 INFO : zwave: node4 valueAdded: 4-156-1-4:Heat = 0
2019-06-29 19:21:23.091 INFO : zwave: Controller Command feedback: DeleteAllReturnRoutes ControllerCommand - Starting node0 retVal:1 state:0
2019-06-29 19:21:23.099 INFO : zwave: Controller Command feedback: DeleteAllReturnRoutes ControllerCommand - InProgress node0 retVal:6 state:0
2019-06-29 19:21:23.268 INFO : zwave: Controller Command feedback: DeleteAllReturnRoutes ControllerCommand - Completed node0 retVal:7 state:0
2019-06-29 19:21:23.270 INFO : zwave: Controller Command feedback: AssignReturnRoute ControllerCommand - Starting node0 retVal:1 state:0
2019-06-29 19:21:23.279 INFO : zwave: Controller Command feedback: AssignReturnRoute ControllerCommand - InProgress node0 retVal:6 state:0
2019-06-29 19:21:23.834 INFO : zwave: Controller Command feedback: AssignReturnRoute ControllerCommand - Completed node0 retVal:7 state:0
2019-06-29 19:21:24.163 INFO : zwave: node4 valueChanged: 4-115-1-0:Powerlevel = Normal dB (no property found)
2019-06-29 19:21:24.165 INFO : zwave: node4 valueChanged: 4-115-1-1:Timeout = 0 seconds (no property found)
2019-06-29 19:21:24.201 INFO : zwave: node4 valueChanged: 4-132-1-0:Wake-up Interval = 21600 Seconds (no property found)
2019-06-29 19:21:34.203 INFO : zwave: node4: timeout
2019-06-29 19:21:42.751 INFO : zwave: node3 valueChanged: 3-49-1-4:Power = 3.6 W (no property found)
2019-06-29 19:21:44.205 INFO : zwave: node4: timeout
2019-06-29 19:21:44.242 INFO : zwave: node4 valueChanged: 4-49-1-1:Temperature = 27.5 C (no property found)
2019-06-29 19:21:44.278 INFO : zwave: node4 valueChanged: 4-49-1-1:Temperature = 27.5 C (no property found)
2019-06-29 19:21:44.353 INFO : zwave: node4 valueChanged: 4-128-1-0:Battery Level = 100 % (no property found)
2019-06-29 19:21:44.390 INFO : zwave: node4 valueChanged: 4-156-1-0:General = 0 (no property found)
2019-06-29 19:21:44.428 INFO : zwave: node4 valueChanged: 4-156-1-2:Carbon Monoxide = 0 (no property found)
2019-06-29 19:21:44.465 INFO : zwave: node4 valueChanged: 4-156-1-4:Heat = 0 (no property found)
2019-06-29 19:21:44.468 ERROR : zwave: Node: 4 unknown genericType: 7
It just means we don't currently have support for command class 156. I've ordered a Fibaro CO sensor, so I should be able to add support as soon as it arrives.
Hi,
I just got a Fibaro CO sensor which is supported by OpenZWave. In the MozillaIoT gateway, it is not recognized as a CO sensor but as a "thing" which displays the temperature and battery life correctly but unfortunately not the CO level.
I looked through the log files and it is apparently able to read the CO value (I think) but it does not show in the gui. I see this
no property found
message on all properties (including the temperature and battery which are correctly displayed in the graphical interface).The other thing is that this device can send alerts! If the CO or temperature exceeds a threshold, it can send an alert message.
I found the table specifying how the CO should be modeled on zwave:
thanks! Sam
The full log is here: