Packet in - packet out constant flow #8

Closed josemariasaldana closed 8 years ago

josemariasaldana commented 8 years ago

Once Odin is running, there are a lot of openflow packet-in packet-out communications between the controller and each AP.

It seems that a rule has to be added to the openvswitch of each AP in order to avoid this. Perhaps a new script can be added for doing this.

josemariasaldana commented 8 years ago

It has been fixed by the addition of a new openflow rule: https://github.com/Wi5/odin-wi5-agent/commit/9d905950174fdb717fd1112b3852368dfaa11490