Closed simplelins closed 1 year ago
Hi @simplelins
Which version of XRT are you using for deployment, and which version of Vivado/Vitis did you use for building the xclbin? Which branch of FINN did you use for the build?
Hi XRT:xrt_202010.2.6.655_18.04-amd64-xrt.deb https://www.xilinx.com/bin/public/openDownload?filename=xrt_202010.2.6.655_18.04-amd64-xrt.deb Vivado/Vitis:2020.1 commit id for FINN:
commit af783db8dc2a1d2e95bd569d39464b935520b6d2 (HEAD -> master, tag: v0.5b, origin/master, origin/HEAD) Author: Yaman Umuroglu yamanu@xilinx.com Date: Thu Dec 17 23:08:20 2020 +0100_
[Docs] bring back missing images
Hi @simplelins, could you please try if your issue persists with the latest FINN release?
I am closing this due to inactivity. Please feel free to reopen or create a new issue if the problem persists!
Hi, I had done a test for using the mobilenetv1 xclbin file with XRT, but when running time,the error reported for argid. and I modify the script 'gen_xo.tcl', when generate xo file.now I can run the mobilenetv1 xclbin file in ALVEO U200 with XRT. when using XRT to run the xclbin file, we need the argid to be a sequense, please check! thanks! I also confused that 'Not applicable for AXI4-Stream ports' , but actually argid for 'AXI4-Stream ports' will cause the error!