Closed ChadMatsalla closed 1 month ago
A7670 is Cat1, Sim7600 is Cat4, the rates are different. Regarding the circuit board, both are the same solution, only the tuner and demodulator are different.
This issue is stale because it has been open for 30 days with no activity.
This issue was closed because it has been inactive for 14 days since being marked as stale.
Hi,
@lewisxhe perhaps?
Can anybody explain the difference between the A7670 and TSIM7600?
I’m interested in battery and solar for a remote location in Canada. Schematics indicate that both have CN3065 for battery charging, both have on-board battery, battery protection
T-SIM 7600 S-8205A for overcharge discharge protection DW01FA for battery management CN3065 for charging ESP32 WROVER JW5222 buck converter ME6217 LDO TCS9208 step-up IO35 for battery voltage
A7670
RS0108YQ20 voltage level converter XC6206P voltage regulator ESP32WROVER DW06D for battery protection CN3065 for charging RT9080 LDO ( or AP2112K )
A7670 seems much cheaper.
Chad