Xinyuan-LilyGO / LilyGO-T-SIM7000G

LilyGO T-SIM7000G
https://pt.aliexpress.com/item/4000542688096.html
284 stars 123 forks source link

Brownout detector was triggered when trying to start the modem using batteries #136

Closed amenoni closed 2 years ago

amenoni commented 2 years ago

Hi. I'm having a Brownout detector was triggered restart when trying to start the modem using a fully charged 18650 battery (4,19v) in the 20-4-15 version. The problem stops if I plug the USB.

do you have any idea how to solve it?

Appreciate your help

edge7 commented 2 years ago

I have got a similar problem. I am trying to mitigate the problem via software (which is doing one operation at a time, for instance, turn off Access Point if the modem is being used), the problem is that the battery cannot provide the peak current the modem needs, something like 450ma at peak. @amenoni just as a curiosity what is your sketch roughly? Are you using GSM or LTE NB-IoT/CAT?

LilyGO commented 2 years ago

Do you have a video? I don't have any of those problems.Something to do with batteries

LilyGO commented 2 years ago

Hello, I will close this issue if it has not resolved you repost your issue