Closed Marcotic closed 1 year ago
THank you so much!!!!
I was able to upload again.
I still have the issue of the battery. Tbeam wont run with battery only. Battery is fully charged. It wont charge it neither. Any advice
Do you have a multimeter? The voltage at these two points can be measured See if it's normal
Measured 4.05 volts.
Did you press the PWR button for two seconds?
Uploaded LoRa sender code form the repo, measured before pressing 4.04, measured after pressing 2sc same 4.04.
Can I turn off the board power supply by pressing and holding the PWR button if I use USB power supply?
Yes. It turns off when holding power button until it stops.
Then measure whether there is voltage at these two points
voltage of the last two points: usb powered: Normal 4.88 after 8 sc holding power 4.95 on battery powered..no red led, 1.32
I just noticed that measuring into first two the points the ones from the https://github.com/Xinyuan-LilyGO/LilyGo-LoRa-Series/issues/87#issuecomment-1486515120 image, it has 3.85volts. I f it helps...
any idea??
Sorry, I forgot to reply to you
Hi. I was having problems with the battery and the axp192 not charging and by mistake i uploaded a code where i set dcd1 voltage to 1.2v. Now my tbeam v1.1 is not booting anymore. Red led lights on boot but immediately shuts down. I cannot upload anymore. Is there a way to reset axp192. Or reflashing the board without using usb? Thanks