Closed GoogleCodeExporter closed 9 years ago
Original comment by mcgra...@gmail.com
on 11 Apr 2008 at 12:19
Which version of FDS are you using? I tried your input file:
ERROR: PART_ID for PROP 3 cannot refer to MASSLESS particles
And could not run the case with the version:
Fire Dynamics Simulator
Compilation Date : Wed, 09 Apr 2008
Version : 5.1.4 Serial
SVN Revision No. : 1548
I took out the SURF_ID='EXHAUST 1' etc control logics and then the
case run.
Next check: I took out the fire mesh line (deleted the "&") and run
just in the evacuation mode and now problems in the geometry.
The (evacuation) OBST were 1.2 in height as they should be, see
the evac-mesh line:
&MESH IJK=216,216,1, XB=-28.0,28.0, -28.0,28.0, 0.4,1.6, EVAC_Z_OFFSET=1.0,
EVACUATION=.TRUE., EVAC_HUMANS=.TRUE., ID = 'FF1stFloor' /
Here you say, that the z is from 0.4m to 1.6m, the mid point is
then at 1.0m ==> EVAC_Z_OFFSET=1.0, so the soldiers will have their
feet at the level z=0.0m.
Ciao,
Timo
Original comment by tkorh...@gmail.com
on 21 Apr 2008 at 10:34
Now I updated my FDS version (was on a conference trip
last week...):
Fire Dynamics Simulator
Compilation Date : Sun, 20 Apr 2008
Version : 5.1.4 Serial
SVN Revision No. : 1593
Now no "ERROR: PART_ID for PROP" problem anymore. But the simulation seems
to run as it should. The evacuation geometry seems to be ok, 0.4m - 1.6m as
defined on the evacuation mesh line.
Timo
Original comment by tkorh...@gmail.com
on 21 Apr 2008 at 12:06
Timo -- I fixed the bug related to PART and PROP. I plan to release FDS 5.1.5
this
week, so let me know if there is more to do on this case.
Original comment by mcgra...@gmail.com
on 21 Apr 2008 at 1:00
Well, the fire and evacuation OBSTs are shown in Smokeview.
The evacuation OBSTs have the same z values as the corresponding
evacuation mesh. This is the reason why you see too high OBSTs
in your Smokeview pictures. There are no easy cure for this.
You could change the color of the OBST in the evacuation mesh,
see the discussion forum topic " Hiding EVAC MESH and objects..".
I'm not going to change this right now. In the future it might
be possible that the Smokeview is changed so that you can easily
choose only fire meshes, only evacuation meshes, or both. But this
is not on the TO DO list yet.
Timo
Original comment by tkorh...@gmail.com
on 4 Aug 2008 at 11:57
Original issue reported on code.google.com by
vich...@gmail.com
on 11 Apr 2008 at 1:55Attachments: