Open YoshinoriFujii opened 5 years ago
The measurement data is stored in
/users/VIS/TypeB/geo_check/forBS/190123/
plot transfer functions from output voltage to the velocity of the mass get the information of t_deacay, f0, Ge by fitting the function with the eq in [1].
The fitting results (raw) are: fitting_results_for_BS.pdf
channel name | Ge | eta | f0 |
---|---|---|---|
CH20 | 269.916375915 +/- 0.000188587927379 | 0.346571105434 +/- 3.00711943235e-07 | 0.983204011539 +/- 1.71568859765e-07 |
CH21 | 269.306243386 +/- 0.000182615347757 | 0.340087429364 +/- 2.88354030819e-07 | 0.987126563661 +/- 1.68207920156e-07 |
CH22 | 270.38483948 +/- 0.000185564029199 | 0.33709611255 +/- 2.79657468877e-07 | 1.0171297833 +/- 1.69051499483e-07 |
CH23 | 273.233487731 +/- 0.000192338064131 | 0.277733478285 +/- 2.27452910585e-07 | 1.23137542287 +/- 1.44064917327e-07 |
TF_geo_BS_CH20.txt TF_geo_BS_CH21.txt TF_geo_BS_CH22.txt TF_geo_BS_CH23.txt
Target
Todo
reference: [1] geo-tf