Open YoshinoriFujii opened 5 years ago
start configuration:
F0GAS -SUsMod looks the latest one.
F1GAS
blue: the currently implemented one
red: which would be tested, the plan 1 (dcdamp_test)
green: the plan 2 (dc_plan)
Should I tale care of infinite amp. at lower frequency?
BFGAS
blue: the currently implemented one
green: which would be tested, the plan 1 (dcdamp_test)
red: the plan 2 (dc_test)
data: /users/VIS/TypeA/general/LogNotes/20190924/ETMX
I have added ~9.7Hz notch to all the F0/1/F3/BF-GAS loops.
sensor polarity looks aligned among the stages at /users/VISsvn/TypeAtower/ETMX/Measurements/TF/Measurements/20190926/F1_GASexc.xml
Note: when the following configuration was used, F1-GAS start ringing up at 2.7Hz:
2019.9.26, I finished with
old filter information:
btw, the modal sensor for Mode1 looks working somehow.
For actuators, starting from (F0, F1, F2,F3, BF) = (1,1,1,1,1), and then diagonalizing it, would work?
stage | current nominal [1] | modification on Nov. 16th [2] |
---|---|---|
F0 | dc+damp (UGF_2Hz) | dc+damp (UGF_4.4Hz) |
F1 | dc | dc |
F2 | --- | --- |
F3 | dc+damp | dc |
BF | dc | dc |
[1] FM5 (blue) [2] FM7 (red)
stage | configuration |
---|---|
F0 | dc+damp (UGF_2Hz) |
F1 | dc |
F2 | --- |
F3 | dc+damp |
BF | dc |
stage | configuration |
---|---|
F0 | dc+damp (UGF_2Hz) |
F1 | dc |
F2 | --- |
F3 | dc |
BF | dc |
Background
Ref