Zapit-Optostim / zapit

General purpose optostimulation system
GNU Lesser General Public License v2.1
6 stars 1 forks source link

Allow system to produce arbitrary number of points in a trial #138

Open raacampbell opened 11 months ago

raacampbell commented 11 months ago

This is largely in place now: f5e8d725177af7a8de18dfd64e9c652b2acb11a7 (and: 8991e7aa7c6b243840b2fd7f0411cae5e09024a3).

The current stimulus pattern is 40 Hz stimulation because we are presenting the stimuli over a 25 ms period. image

raacampbell commented 11 months ago

Looking on the scope, I see no difference in blanking behavior between the ad-hoc and filtered versions of the command waveforms. Good!

raacampbell commented 11 months ago

The convolution is good and does not alter the waveforms in any significant way eca2edea0d00ec9eb544d5dcd141031ad6a4d195

raacampbell commented 8 months ago

See bug #150 related to this new feature.

raacampbell commented 4 months ago

It is now very clear in the instructions that the user is responsible for measuring power per point. So maybe we don't need to limit max points.