Open MumuMaster2021 opened 5 months ago
Can you upload your ABACUS input files to repeat your results?
Another question is what is the E_Fermi
value from ABACUS?
The zero energy point of output DOS file from ABACUS is not the Fermi energy.
Hi,daye This zip includes two structure results calculated by vasp and abacus. 来自飞书邮箱的超大附件 [image: https://sf1-cdn-tos.douyinstatic.com/obj/eden-cn/fuupceh7nupfnupfnuhog/icon_file_unknow.png] issue-322.tar.gz 208.7 MB将于 Jun 13, 2024 失效 下载https://www.feishu.cn/mail/page/attachment?token=R9GgbPIe5oHL1YxckwJczcranac
From: @.> Date: Tue, May 28, 2024, 23:11 Subject: Re: [abacusmodeling/abacus-develop] Difference of DOS between the amorphous structure relaxed by vasp and abacus (Issue #322) To: @.> Cc: @.>, @.> Can you upload your ABACUS input files to repeat your results? Another question is what is the E_Fermi value from ABACUS?
The zero energy point of output DOS file from ABACUS is not the Fermi energy. — Reply to this email directly, view it on GitHubhttps://github.com/abacusmodeling/abacus-develop/issues/322#issuecomment-2135476951, or unsubscribehttps://github.com/notifications/unsubscribe-auth/BCDP6QRMQCUWHHMI6FLKPETZESNBVAVCNFSM6AAAAABINBBEXCVHI2DSMVQWIX3LMV43OSLTON2WKQ3PNVWWK3TUHMZDCMZVGQ3TMOJVGE. You are receiving this because you authored the thread.[image: https://github.com/notifications/beacon/BCDP6QUK6F3D53OFJXISTKDZESNBVA5CNFSM6AAAAABINBBEXCWGG33NNVSW45C7OR4XAZNMJFZXG5LFINXW23LFNZ2KUY3PNVWWK3TUL5UWJTT7JDFNO.gif]Message ID: @.***>
we use config.json , and execute abacus plot 功能 { "pdosfile": "PDOS", "efermi": 2.5311038583, "energy_range": [ -5, 5 ], "dos_range": [ 0, 10 ], "figsize": [ 14, 10 ], "species": { "Si": [ 0, 1, 2 ], "O": [ 0, 1, 2 ], "Bi": [ 0, 1, 2, 3 ] }, "pdosfig": "pdos.png" }
@MumuMaster2021 I checked the band energys and occuaptions from VASP, which imply a small bandgap semi-conductor as well as ABACUS.
I also notice that the smearing_sigma 0.01
in ABACUS(unit: Ry) is larger than SIGMA 0.05
in VASP(unit: eV), you can try smearing_sigma 0.0037
in ABACUS and recalculate this case.
Describe the Code Quality Issue
We provide four amorphous structures, Ge10_Bi2_Si59_O143, which use vasp and abacus to relax, and then perform dos calculation after convergence. The results show that the dos calculation of the structure after abacus srelax indicates that it is a conductor, and the optimized configuration after vasp is a semiconductor. According to experience, we prefer this amorphous structure to be a semiconductor. May I ask whether the accuracy of abacus' relax configuration is insufficient or whether other reasons lead to the difference between the above two calculation software results in the convergent configuration?
Additional Context
No response
Task list for Issue attackers (only for developers)