Open kARTechnology opened 2 years ago
Also the existing mhi-ac-ctrl doesn't respond when the ac has been shutdown and in self clean state/finished self clean state.
Thanks for providing your logs. I have also the impression that the commands are not visible on the SPI. That matches my previous experiences. If you have a look on the user manual of commercial remote controls (e.g. RC-E5) you will see that only a small subset of commands which can be triggered by the IR-RC are supported by the SPI based RC.
pls check if my findings are correct: DB0 on: 49 off: 48 self clean: 4d so it switches to fan mode in self clean..but no inference to send command from spi?
According to SPI.md the DB0 values have the following meaning: on:49 = Vanes swing, COOL, Power on off:49 = Vanes swing, COOL, Power off self clean:4d = Vanes swing, FAN, Power on I can't see something specific to self clean. According to the issue "SELF CLEAN operation" to prevent mold #67 the fan works for about 2h. You could check if the fan off command after 2h is triggered by the IR-RC to find out if self clean is a function of the AC or a (macro) function of the IR-RC. This could be similar to the timer functions of the IR-RC. As far as I know this is completely controlled by the IR-RC, not by the AC itself (when you carry the IR-RC in another room without visual connection to the AC I assume a programmed timer doesn't work.) - best guess, I never tested it.
Even if the remote Is in aother room, ac turns off. Also the power led keeps blinking in self clean, which means it's a macro in the ac and not on the remote.. Similarly turbo mode turns on the turbo led on ac. 3d auto turns on 3d auto led on ac
On Tue, 21 Dec, 2021, 11:51 pm absalom-muc, @.***> wrote:
According to SPI.md https://github.com/absalom-muc/MHI-AC-Trace/blob/main/SPI.md the DB0 values have the following meaning: on:49 = Vanes swing, COOL, Power on off:49 = Vanes swing, COOL, Power off self clean:4d = Vanes swing, FAN, Power on I can't see something specific to self clean. According to the issue "SELF CLEAN operation" to prevent mold #67 https://github.com/absalom-muc/MHI-AC-Ctrl/issues/67#issue-941445400 the fan works for about 2h. You could check if the fan off command after 2h is triggered by the IR-RC to find out if self clean is a function of the AC or a (macro) function of the IR-RC. This could be similar to the timer functions of the IR-RC. As far as I know this is completely controlled by the IR-RC, not by the AC itself (when you carry the IR-RC in another room without visual connection to the AC I assume a programmed timer doesn't work.) - best guess, I never tested it.
— Reply to this email directly, view it on GitHub https://github.com/absalom-muc/MHI-AC-Trace/issues/2#issuecomment-998996597, or unsubscribe https://github.com/notifications/unsubscribe-auth/AF6ODFPVSNUN6QNKCSL5DQ3USDARHANCNFSM5KMD7JTQ . Triage notifications on the go with GitHub Mobile for iOS https://apps.apple.com/app/apple-store/id1477376905?ct=notification-email&mt=8&pt=524675 or Android https://play.google.com/store/apps/details?id=com.github.android&referrer=utm_campaign%3Dnotification-email%26utm_medium%3Demail%26utm_source%3Dgithub.
You are receiving this because you authored the thread.Message ID: @.***>
ah o.k. I have not so many LEDs. Then my assumption related to the timer might be also wrong. However, I have still no idea how to activte these additional functions via SPI.
Hi,
I did some traces on my SCM 45-ZS-W & SRK 35-ZS-W too. May just for reference.
Vanes L/R: none!
3D Auto: none!
Silent: none!
Sleep: none!
Timer: none!
ON/OFF -> CLEAN! (2x)
14 de 6d 80 04 0c 12 2c 91 00 00 88 00 ff ff ff ff ff 00 00 07 4f ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff 59
16 11 6d 80 04 0d 12 2c 91 00 00 88 00 ff ff ff ff ff 01 00 07 51 ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff 32
16 67 6d 80 04 0c 12 2c 91 00 00 88 00 ff ff ff ff ff 00 00 07 4f ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff 55
16 ab 6d 80 04 0d 12 2c 91 00 00 88 00 ff ff ff ff ff 01 00 07 51 ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff 43
Night-SetBack (3x):
23 dc 6d 80 04 11 12 14 92 00 00 80 02 ff ff ff ff ff 07 00 07 3e ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff 38
24 04 6d 80 04 11 12 2c 92 00 00 80 02 ff ff ff ff ff 07 00 07 56 ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff 27
24 44 6d 80 04 11 12 14 92 00 00 80 02 ff ff ff ff ff 07 00 07 3e ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff 3f
24 65 6d 80 04 11 12 2c 92 00 00 80 02 ff ff ff ff ff 07 00 07 56 ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff 20
24 89 6d 80 04 11 12 14 92 00 00 80 02 ff ff ff ff ff 07 00 07 3e ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff 23
24 a9 6d 80 04 11 12 2c 92 00 00 80 02 ff ff ff ff ff 07 00 07 56 ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff 1f
Normal/HighPower/Eco (3x):
27 59 6d 80 04 11 10 2c 93 00 00 80 02 ff ff ff ff ff 07 00 07 55 ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff af
27 73 6d 80 04 11 12 2c 93 00 00 80 02 ff ff ff ff ff 07 00 07 57 ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff 19
27 c6 6d 80 04 11 10 2c 93 00 00 80 02 ff ff ff ff ff 07 00 07 55 ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff 52
27 dd 6d 80 04 11 12 2c 93 00 00 80 02 ff ff ff ff ff 07 00 07 57 ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff 16
28 2d 6d 80 04 11 10 2c 93 00 00 80 02 ff ff ff ff ff 07 00 07 55 ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff 4f
28 5a 6d 80 04 11 12 2c 93 00 00 80 02 ff ff ff ff ff 07 00 07 57 ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff 2c
self clean captured. swing L/R U/D doesnt reflect changes immediately, even silent mode/ 3d auto. i've tried to capture by setting it in respective modes and turning on ac.