GiorgosM1995 commented 5 months ago

Payload after reset (Boot payload) : 5230332e36362b33302e3056312e342e30 , 5231332e36362b33302e3056312e342e30 Occupation Status Change : 4330 , 4331 Status Report(Keep-Alive) : 4B30332E35352B32322E30 , 4B31332E35352B32322E30 Device Malfunction Payload : 45332E3535112233

tomHallActility commented 5 months ago

Hello @GiorgosM1995,

Thank you for these additional payload examples.

Device Malfunction Payload : 45332E3535112233 This payload, through your decoder, gives me the following data output: "batteryVoltage": "3.55V", "messageType": "Malfunction", "statusReport": "◄\"3"

Is it the expected statusReport value?

GiorgosM1995 commented 5 months ago

Yes it give us a report for interval RnD and testing so i wrote some random bytes

Best Regards

Georgios Mouratidis

IoT Engineer

[cid:a5d285b5-848c-45ff-a4aa-cd3dfdaa625f]

Kosta Varnali 12

15233 Chalandri, Athens, Greece

Tel: +30 210 6391072 (Ext. 650)

Email: @.**@.> | Web: www.cicicom.grhttp://www.cicicom.gr/

[cid:ccdc5e32-d169-4c74-b60a-59dc67b47b95]

This e-mail (including any attached documents) is proprietary and confidential and may contain legally privileged information. It is intended for the named recipient(s) only. If you are not the intended recipient, you may not review, retain, copy or distribute this message, and we kindly ask you to notify the sender by reply e-mail immediately and delete this message from your system. Thank you.

E-mail is susceptible to unauthorized alterations which may corrupt the message of the e-mail. Our Company only sends and receives e-mails on the basis that is not liable for any unauthorized alterations made to the e-mails.


Από: tomHallActility @.> Στάλθηκε: Τρίτη, 9 Απριλίου 2024 4:26 μμ Προς: actility/device-catalog @.> Κοιν.: George Mouratidis @.>; Comment @.> Θέμα: Re: [actility/device-catalog] TXIF-2835 - Adding examples and sensors to Cicicom Parking Sensor S-LG-I3 model (PR #127)

Hello Giorgos,

Thank you for these additional paylaod examples.

Device Malfunction Payload : 45332E3535112233 This payload, through your decoder, gives me the following data output: "batteryVoltage": "3.55V", "messageType": "Malfunction", "statusReport": "◄"3"

Is it the expected statusReport value?

— Reply to this email directly, view it on GitHubhttps://github.com/actility/device-catalog/pull/127#issuecomment-2045177132, or unsubscribehttps://github.com/notifications/unsubscribe-auth/BGFWAQJQUAZWGGJ2LFGJVBTY4PT7NAVCNFSM6AAAAABFXRM2C6VHI2DSMVQWIX3LMV43OSLTON2WKQ3PNVWWK3TUHMZDANBVGE3TOMJTGI. You are receiving this because you commented.Message ID: @.***>

tomHallActility commented 5 months ago

Ok, thank you. Can you tell me which bytes correspond to the status report so I can change the characters, please? (Testing is slightly blocked because of these special characters for now) Thank you in advance.

GiorgosM1995 commented 5 months ago

Both of the payloads

Best Regards

Georgios Mouratidis

IoT Engineer

[cid:316a7808-b24a-46e0-afc1-c46beddd664e]

Kosta Varnali 12

15233 Chalandri, Athens, Greece

Tel: +30 210 6391072 (Ext. 650)

Email: @.**@.> | Web: www.cicicom.grhttp://www.cicicom.gr/

[cid:38d80984-48aa-4038-95b9-4bfd752ada0f]

This e-mail (including any attached documents) is proprietary and confidential and may contain legally privileged information. It is intended for the named recipient(s) only. If you are not the intended recipient, you may not review, retain, copy or distribute this message, and we kindly ask you to notify the sender by reply e-mail immediately and delete this message from your system. Thank you.

E-mail is susceptible to unauthorized alterations which may corrupt the message of the e-mail. Our Company only sends and receives e-mails on the basis that is not liable for any unauthorized alterations made to the e-mails.


Από: tomHallActility @.> Στάλθηκε: Τρίτη, 9 Απριλίου 2024 5:26 μμ Προς: actility/device-catalog @.> Κοιν.: George Mouratidis @.>; Mention @.> Θέμα: Re: [actility/device-catalog] TXIF-2835 - Adding examples and sensors to Cicicom Parking Sensor S-LG-I3 model (PR #127)

Ok, thank you. Can you tell me which bytes correspond to the status report so I can change the characters, please? (Testing is slightly blocked because of these special characters for now) Thank you in advance.

— Reply to this email directly, view it on GitHubhttps://github.com/actility/device-catalog/pull/127#issuecomment-2045315933, or unsubscribehttps://github.com/notifications/unsubscribe-auth/BGFWAQPCIBVZLLIKVONAOT3Y4P3DHAVCNFSM6AAAAABFXRM2C6VHI2DSMVQWIX3LMV43OSLTON2WKQ3PNVWWK3TUHMZDANBVGMYTKOJTGM. You are receiving this because you were mentioned.Message ID: @.***>

tomHallActility commented 5 months ago

Sorry for the confusion. I meant in the Device Malfunction Payload example. I changed it to 45332E3535212121 and got "statusReport": "!!!" instead of "statusReport": "◄\"3".

Thank you for your help.

GiorgosM1995 commented 5 months ago

Yes you can leave it like this Malfunction Payload : 45332E3535