Closed zorak1103 closed 1 week ago
Hi
Which version of the integration are you using? On 0.4.6 this should be fixed and you should not be getting those values anymore.
This happend with 0.4.4. Just updated to 0.4.6. Will keep an eye on it. Great work!
Great. Let me know if it works well, but for me it has been working fine and generic responses are not being parsed to the sensors.
@zorak1103
Did the 0.4.6 fix the issue?
yes, the fix was successful. no more strange values. thanx alot!
Good to know. Thanks
Sometimes Electric Range and State of Charge report unrealistic values.
Either SoC of 102% and 0% is unrealistic, as is Electric Range of 2046 km or 0 km.
Maybe it would be possible to define cutoff values or a valid range for the integration.