aesim-tech / simba-project

Roadmap & issue tracking
7 stars 0 forks source link

Impossible to assign one .XML description of a diode #313

Closed guillaumefontes closed 1 year ago

guillaumefontes commented 1 year ago

Found a description of a diode (which uses formula and custom variables) which leads to a crash. IKW50N120CS7

  1. The thermal description can be created with the .XML file importation,
  2. When we try to assign this thermal description to a diode, Simba crashes.

It seems to have a link with the custom variable 'Rg'. Indeed if this last one is deleted, the assignation does not crashes anymore.

image

IKW50N120CS7.zip

manu-aesim commented 1 year ago

Thanks for the issue. This is now fixed.

The error was due to one custom table that was not working properly in our interpolator.