Closed guillaumefontes closed 11 months ago
Example with a sine source @50Hz with a probe. Let's try to sample the output of this probe at 1e-3s.
With predictive time-step, it is OK. With fixed time-step @1e-7s, it gives strange values for the first periods of the sine.
You can find simulation file below. Results considered with beta version of 14-09. possible-bug-zoh.zip
BR
This bug was caused by a numerical rounding error and should be solved in this release:
https://aesimtech.s3.us-east-1.amazonaws.com/artifacts/AeCrxoW3vjiMF3wakZNSLJSalO2bGwVO/simba.exe
Example with a sine source @50Hz with a probe. Let's try to sample the output of this probe at 1e-3s.
With predictive time-step, it is OK. With fixed time-step @1e-7s, it gives strange values for the first periods of the sine.
You can find simulation file below. Results considered with beta version of 14-09. possible-bug-zoh.zip
BR