It is not possible to read property extPowerPresent (PIN 8) from Power service (SIN 17) by sending getProperties message (MIN 8, SIN 16). There is no response send after request.
What is important there are no problems in reading other Power service properties like PIN 7 or PIN 9 (response sent with properties values). This problem applies to lsf.getProperties command as well as sending getProperties message directly from Modem Simulator.
Steps to reproduce:
Prerequisite: IDP 800 terminal simulated
Send getProperties to-mobile message (MIN 8, SIN 16) with content : sin = 17, pinList = 8
Message correctly sent (present in To-Mobile Messages section in Modem Simulator) but no response received.
It is not possible to read property extPowerPresent (PIN 8) from Power service (SIN 17) by sending getProperties message (MIN 8, SIN 16). There is no response send after request. What is important there are no problems in reading other Power service properties like PIN 7 or PIN 9 (response sent with properties values). This problem applies to lsf.getProperties command as well as sending getProperties message directly from Modem Simulator.
Steps to reproduce: Prerequisite: IDP 800 terminal simulated
version of Modem Simulator: 2.0.6