Open piousdeer opened 2 years ago
Can you send PR since I do not have this hardware for tests
Apparently proxy.State
reports charging even when the BAT0/status
is unknown, so I'm not sure where to go with this. When battery level reaches 60%, proxy.TimeToFull
is set to 0, but charging can be stopped before that, at 58 or 59 %. This probably needs to be adressed in UPower.
On my Lenovo Legion laptop, and probably on other Lenovo laptops, when battery conservation mode is enabled and the battery level reaches the threshold (which can be 58 to 60 %),
/sys/class/power_supply/BAT0/status
reportsUnknown
. It'd be great if this extension supported this to avoid having to manually change the maximum charging level from 100% to 58% and vice versa whenever the conservation mode is toggled.