Hi @alengwenus,

thank you very much for your effort. The sml component works great for me.

Do you plan to add support for sending a PIN to the meter?

I use a Holley DTZ541, unfortunately it emits only very basic OBIS data unless a PIN is submitted:

But after a PIN is supplied, it will send these additional values:

Best regards, // Veit

alengwenus commented 2 years ago

All energy meters I know have a button or can be flashed using a torch to enter the PIN. Doesn't that work with your energy meter?

veitw commented 2 years ago

It has one, it also shows the extended values on the display screen after entering the PIN.

But after a minute or so, it returns to the basic values and one has to re-enter the PIN. Thus the question whether you plan extend the component to submit the PIN to the smart meter.

BMOD89 commented 2 years ago

I have checked the manual of your meter. There is the possibility to disable the pin retrieval. With that option you should be able to continuously see all values.

veitw commented 2 years ago

This is what I had already configured:

It gave me only the information described above.

@BMOD89: Do you have a real manual for this device? So far I only found some very basic guides, mostly like quick start guides for the menu.

BMOD89 commented 2 years ago

I guess it is the same manual: https://www.holleytech.de/wp-content/uploads/2021/03/Benutzerhandbuch_mME-DTZ541_V2.0.pdf

I have a different meter, but the principle (menu and so on) is similar and for my meter it is sufficient to set the values as you just described.

I am not 100% sure but I think the optical interface is only unidirectional. So you cannot set a pin via the optical interface. At least I haven't read about that possibility yet...

veitw commented 2 years ago

@BMOD89: Thank you very much. From this document I learned that, differing from the quick start guide, the power meter does not have two but three different modes for the D0 interface; "reduced", "complete" and "manufacturer-specific" data set -- and the additional information I'd like to monitor, which was said to be available in the quick start guide, is only transmitted in the manufacturer-specific mode.

Regarding to the manual, this mode can be enabled via the "rear interface" -- whatever that exactly means, as it is nowhere mentioned again in the manual...

veitw commented 2 years ago

Regarding to the manual, this mode can be enabled via the "rear interface" -- whatever that exactly means, as it is nowhere mentioned again in the manual...

It seems that "rear interface" refers to the RS485 port, which is in fact on the front of this power meter, but not accessible to the consumer. :(