During this test we will apply gentle pressure in different ways on the PCB.
Test Execution
Manual
Objective
The goal of this test is to measure how the custom PCB reacts to tension (mechanical) to see ensure its robustness and solidity.
Test Environment
Other
Dependencies
The PCB
Preconditions
Nothing else than the soldered components should be connected to the device.
Post-conditions
The device should be in the same state after test completion.
Test Data
In the following images, a plastic card will represent the PCB:
[!CAUTION]
The pressure shown in the following images is exaggerated for demonstration purposes, please apply appropriate pressure on the device (not more pressure than you would need to press a button for instance)
Step 0: Hold the PCB correctly...
![Image](https://github.com/algosup/2023-2024-project-4-sportshield-team-7/assets/114522530/5fb277b2-d3a3-4c86-90cc-65f954f98473)
Step 1: Twist Test 1
![Image](https://github.com/algosup/2023-2024-project-4-sportshield-team-7/assets/114522530/63f50d63-f462-44cc-bd17-624c4a3db70a)
Step 2: Twist Test 2...
![Image](https://github.com/algosup/2023-2024-project-4-sportshield-team-7/assets/114522530/9b91efe9-3126-4c96-9cb7-4e4ac54d57f4)
Step 3: Flex Up Test...
![Image](https://github.com/algosup/2023-2024-project-4-sportshield-team-7/assets/114522530/efc89ee1-d173-4f37-8e83-9a0218b18c97)
Step 4: Flex Down Test...
![Image](https://github.com/algosup/2023-2024-project-4-sportshield-team-7/assets/114522530/d5595cba-59f1-46c8-8d7f-6c6788011bb0)
Steps
Step ID
Step Description
Step Date
Expected Results
Actual Results
Pass / Fail
Add. Notes
O
Hold the PCB correctly
04/18/2024 - 18:51
Nothing should break, no cracking sound should occur
Nothing broke, no cracking sound occurred
PASS
1
Twist Test 1
04/18/2024 - 18:52
Nothing should break, no cracking sound should occur
Nothing broke, no cracking sound occurred
PASS
3
Twist Test 2
04/18/2024 - 18:53
Nothing should break, no cracking sound should occur
Nothing broke, no cracking sound occurred
PASS
4
Flex Up Test
04/18/2024 - 18:54
Nothing should break, no cracking sound should occur
Nothing broke, no cracking sound occurred
PASS
5
Flex Down Test
04/18/2024 - 18:55
Nothing should break, no cracking sound should occur
Test Case Title
PCB Tension Checks
Test Status
Passed
Test Description
During this test we will apply gentle pressure in different ways on the PCB.
Test Execution
Manual
Objective
The goal of this test is to measure how the custom PCB reacts to tension (mechanical) to see ensure its robustness and solidity.
Test Environment
Other
Dependencies
Preconditions
Nothing else than the soldered components should be connected to the device.
Post-conditions
The device should be in the same state after test completion.
Test Data
In the following images, a plastic card will represent the PCB:
Step 0: Hold the PCB correctly...
![Image](https://github.com/algosup/2023-2024-project-4-sportshield-team-7/assets/114522530/5fb277b2-d3a3-4c86-90cc-65f954f98473)Step 1: Twist Test 1
![Image](https://github.com/algosup/2023-2024-project-4-sportshield-team-7/assets/114522530/63f50d63-f462-44cc-bd17-624c4a3db70a)Step 2: Twist Test 2...
![Image](https://github.com/algosup/2023-2024-project-4-sportshield-team-7/assets/114522530/9b91efe9-3126-4c96-9cb7-4e4ac54d57f4)Step 3: Flex Up Test...
![Image](https://github.com/algosup/2023-2024-project-4-sportshield-team-7/assets/114522530/efc89ee1-d173-4f37-8e83-9a0218b18c97)Step 4: Flex Down Test...
![Image](https://github.com/algosup/2023-2024-project-4-sportshield-team-7/assets/114522530/d5595cba-59f1-46c8-8d7f-6c6788011bb0)Steps
Notes
No response