allpowerlabs / KS_Engine3

KS_Engine3 is the depreciated sketch used to run the Power Pallet
3 stars 2 forks source link

Shut down engine after 360 seconds of auger being on (reactor not refilling) #20

Open allpowerlabs opened 12 years ago

allpowerlabs commented 12 years ago

Update alarm to 240 seconds (4 minutes) of auger being on. Shut engine off at 360 seconds (6 minutes) of auger being on.