I have "successfully" implemented an ISO-15693. Using the PM3 with a TI-
TRF7960 Reader/writer I can respond to an Inventory command and read block
command and a Write-with-Password command. This work\s with a single and
double subcarrier request.
My problem is that the system does not work with the third party ready I am
trying to attach. when I snoop the reader with an actual Tag present i get
25010092E5
*** Inventory One slot - dual subcarrier
41200055B9
*** Read Block 00 - dual subcarrier - option flag
412001DCA8
*** Read Block 01 - dual subcarrier - option flag
412002479A
*** Read Block 03 - dual subcarrier - option flag
412003CE8B
*** Read Block 03 - dual subcarrier - option flag
61A50792722B6028C507E03C0B9E8B03000000004708 *** Write with Pwd block 03 -
dual subcarrier - address - opt
412003CE8B
*** Read block 03 check if write was successful
When I replace the Tag with the PM3 all I get is the inventory Command -
25010092E5. So I guess the reader is not getting the response from the PM3.
Yet the PM3 tag simulator can successfully respond to all these commands using
the TI- TRF7960 Reader/writer.
Can anyone explain why the the Tag Simulator would work with the TI system and
not the unknown reader?
The relevant code is attached.
Note: for the short term I have changed hi_simulate for ISO15693 tag
modulation. Once this is working, I will add a new 15692 module.
Original issue reported on code.google.com by G.H.G...@gmail.com on 14 Jul 2010 at 1:49
Original issue reported on code.google.com by
G.H.G...@gmail.com
on 14 Jul 2010 at 1:49Attachments: