Closed djcopley closed 6 years ago
https://github.com/analogdevicesinc/gr-iio/blob/5de3bb8fecf0aefb20802c243f1d69bb8c521aaa/lib/device_source_impl.cc#L258-L263
If you want a block of code to get run at program termination, override the stop method from the gr::block class.
You do override stop. Oversight.
https://github.com/analogdevicesinc/gr-iio/blob/5de3bb8fecf0aefb20802c243f1d69bb8c521aaa/lib/device_source_impl.cc#L258-L263
If you want a block of code to get run at program termination, override the stop method from the gr::block class.