andrivet / ADVi3pp

ADVi3++, an alternative and better firmware for Wanhao i3 Plus printers and clones. Fork of Marlin Firmware.
https://community.advi3pp.com
GNU General Public License v3.0
243 stars 119 forks source link

Update description of Print Settings panel #308

Closed DimitryNechaev closed 2 years ago

DimitryNechaev commented 2 years ago

When accessing updated print settings panel I don't understand some functions which are not described in the manual https://manual.advi3pp.com/en/touch-panel-guide/print/print-settings

The panel has 2 settings.

  1. A setting under baby stroller with value 0.04
  2. A setting with a switch options 0.02, 0.1 and 1.00

The manual has reference to baby stepping, but it is not clear

Please make it more clear as it is unusable for me at the moment w/o support

andrivet commented 2 years ago

I will add a category for the manual (defect or suggestions). I will look at this soon

andrivet commented 2 years ago

I will enhance the documentation. In the meantime, here is a description from Marlin’s documentation (Babystep | Marlin Firmware):

Apply babysteps to one or more axes using current units. Offsets applied with M290 aren’t added to the current coordinates, but are intended for making small adjustments, especially in the Z axis, at the start of a print.

Note that when BABYSTEP_ZPROBE_OFFSET is enabled, M290 also modifies the Probe Z Offset (with no immediate effects). The new Z offset applies to successive probing operations, and can be saved with M500. This behavior is means to coincide with the LCD Menu replacing “Z Babystepping” with “Babystep Z Probe Offset.” To avoid this side-effect, use M290 P0 or leave ?BABYSTEP_ZPROBE_OFFSET disabled. For ADVi3++, BABYSTEP_ZPROBE_OFFSET is enabled. Pressing the checkmark triggers a M500.

See also: https://community.advi3pp.com/t/missing-how-to-manually-input-z-offset-information-on-5-4/4386/8