antoniograzioli / Autodafe

Autodafe Module Pack for VCV Rack
http://www.autodafe.net/virtual-instruments/vcv-rack-modules/autodafe-module-pack-for-vcv-rack.html
Other
31 stars 7 forks source link

Bitcrusher - Samplerate seems to be global across all instances #12

Open Terfo opened 6 years ago

Terfo commented 6 years ago

Set up a Fundamental.VCO-1 to bitcrusher, and if works fine. Change bits and sample rate to minimum (so you can hear it working) Add another bitcrusher (or duplicate) without connecting it to anything. The sound changes.

Turn the sample rate knob on the new, unconnected bitcrusher, and it will affect the connected one too. When the unconnected bitcrusher is deleted, the first connected one works as it should, and the sound seems to be OK too.

It seems like the "Samplerate" variable is shared between all instances of the Bitcrusher. If you have 3, all three will be adjusted by turning the know on one of them, but the knob position will be changed only on the one you change.

(Rack. v.0.5.0 Windows 10 64bit.)

antoniograzioli commented 6 years ago

It should be fixed in the last binary release of my modules collection...please donwload it and report, thanks