This showed me a lot of errors in the following sheet's respective cells.
First I fixed,
Sour Gas reinjection compressor cell M78 and M79 changed to M77 and M78.
A similar fix needs to be done for CO2 reinjection compressor, M66, and M67 changed to M65 and M66.
VRU compressor M63, and M64 changed to M62 and M63.
Storage Compressor M62, and M63 changed to M61 and M62.
Post-Storage Compressor M62, and M63 changed to M61 and M62.
Then in Electricity Gen and Imports sheet,
Cell M45, please change to
='Sour Gas Reinjection Compressor'!I91
After making this all changes, the CI for CO2-EOR looks more representative compared to literature.
@JSRuthe @smasnadi . Can you please confirm these changes?