This repository contains the software and hardware for a low-cost and handheld system for the identification of plastic types based on discrete near infrared (NIR) reflectance spectroscopy.
In your BOM you are using 1206LEDs. How are you controlling the wavelength for each LED, is it a filter, by sorting (like with resistors) or actually a different LED spec per wavelength?
The system uses discrete Near-Infrared LEDs. Therefore you will need LEDs with different wavelength specifications. We previously sourced them via DigiKey. The manufacturer is Marktech Optoelectronics.
In your BOM you are using 1206LEDs. How are you controlling the wavelength for each LED, is it a filter, by sorting (like with resistors) or actually a different LED spec per wavelength?