Closed timcallow closed 1 year ago
All modified lines are covered by tests :white_check_mark:
Comparison is base (
2dc1caa
) 91.56% compared to head (dd36ba1
) 91.56%.
:umbrella: View full report in Codecov by Sentry.
:loudspeaker: Have feedback on the report? Share it here.
As raised in #186, the current defaults in atoMEC were those implemented at the very start and are now known to be quite poor. In fact they should be used under almost no circumstances.
The convergence defaults are based on analysis of convergence parameters from >2000 calculations for a range of temperatures and densities.
Strictly, changing the defaults should be part of a new major release. However, since we don't change the API in a fundamental way, these changes will be part of the next minor release.