Vent Area Limit Documentation #19

Closed GoogleCodeExporter closed 9 years ago

GoogleCodeExporter commented 9 years ago
The CFAST Technical Manual (SP1026, page 9) recommends that the ratio of 
vent area connecting two compartments and the smaller compartment volume 
should not exceed 2 m^-1.  This value seems high.  A double door 
arrangement on a 3 meter x 3 meter room has an area to volume ratio of 
about 0.2.  Is 0.2 the correct value to present in SP1026?

Original issue reported on code.google.com by allan.co...@wsms.com on 28 Mar 2008 at 5:51

GoogleCodeExporter commented 9 years ago
We've revised the documentation to correct the text.  Our intention was to 
insure 
that the vent does not get too large in relation to the room size.  A ratio of 
the 
room volume to vent area (not the other way around) of about 2 m is now used in 
the 
documentation.

Original comment by cfastdev@gmail.com on 5 Jun 2008 at 7:30