autopower / thermeq3

Boiler actor device for ELV/EQ-3 MAX! cube
GNU General Public License v3.0
19 stars 13 forks source link

disable the duty circle. #8

Closed chrisj8727 closed 7 years ago

chrisj8727 commented 8 years ago

it is possible to disable the duty circle. This is annoying especially during testing. thanks in advance chris

autopower commented 8 years ago

What you mean by duty circle?

chrisj8727 commented 8 years ago

The duty cycle describes a statutory limit of the airtime of devices in the 868 MHz range. The objective of this scheme is to the function of all in the 868 MHz range to ensure working devices. In the frequency range used by us, the maximum transmission time of each unit 868 MHz is 1% of one hour (so 36 seconds in an hour). The devices may be used in achieving the 1%-limit no longer send, until the time limit is over.

chris

2016-09-21 6:42 GMT+02:00 Michal Cheben notifications@github.com:

What you mean by duty circle?

— You are receiving this because you authored the thread. Reply to this email directly, view it on GitHub https://github.com/autopower/thermeq3/issues/8#issuecomment-248510058, or mute the thread https://github.com/notifications/unsubscribe-auth/AO_CMQc8uD4-ZwYoTT-8QV4MlwhSOhHaks5qsLWbgaJpZM4J2y0P .

autopower commented 8 years ago

Thermeq3 does not manipulate communication between device and cube in any way, so informatiom stored "in cube" is based on normal transmission between device and cube.