Open AlexBrad1eyCT opened 3 years ago
Stationing uses two particular Psets (Pset_Stationing and optionally Pset_LinearRefereningMethod) assigned to IfcReferent (PsetStatkoing and optionally Pset_LInearReferencingMethod) or IfcAlignment (optionally Pset_LinearReferencingMethod). It also uses the already defined CT regarding referent nesting which needs documentation text - and shouldn't IfcElement be specialized to IfcReferent in that CT?. To specify a station for a product, the existing CT product relative positioning is used (referencing an IfcReferent/Pset_Stationing).
I would assume that Stationing includes only the part where stations along an alignment is handled and not positioning a product relative to a station/IfcReferent (which is Product Relative Positioning). I interpret the discussion like this:
Description & Tasks
Template for the sematic definition of Stations in linear infrastructure
Discussion Points
Links
Miro Element Miro Task Card
Decisions
This subject is defined as a General Usage, and is not an additional template. it is about defining certain structures and PSets.