Closed ghost closed 12 years ago
New product don't work with current script.
sample log from RFXManager.
Stephane..
Reset receiver/transceiver:0D 00 00 00 00 00 00 00 00 00 00 00 00 00
Get Status:0D 00 00 01 02 00 00 00 00 00 00 00 00 00
0D01000102531F004F6F00000000 Packettype = Interface Message subtype = Interface Response Sequence nbr = 1 response on cmnd = Get Status Transceiver type = 433.92MHz Firmware version = 31 Undec off X10 enabled ARC enabled AC enabled HomeEasy EU enabled Ikea Koppla disabled Oregon Scientific enabled ATI enabled Visonic disabled Mertik enabled LightwaveRF enabled Hideki enabled La Crosse enabled FS20 disabled ProGuard disabled RFU protocol 7 disabled
08500100040100C879 Packettype = TEMP subtype = TEMP1 - THR128/138, THC138 channel 1 Sequence nbr = 0 ID = 1025 Temperature = 20 °C Signal level = 7 Battery = OK
0B110001004B949E0A000050 Packettype = Lighting2 subtype = AC Sequence nbr = 1 ID = 04B949E Unit = 10 Command = Off Signal level = 5
08500102040100C879 Packettype = TEMP subtype = TEMP1 - THR128/138, THC138 channel 1 Sequence nbr = 2 ID = 1025 Temperature = 20 °C Signal level = 7 Battery = OK
0B110003004B949E0A010F60 Packettype = Lighting2 subtype = AC Sequence nbr = 3 ID = 04B949E Unit = 10 Command = On Signal level = 6
0B110004004B949E0A010F50 Packettype = Lighting2 subtype = AC Sequence nbr = 4 ID = 04B949E Unit = 10 Command = On Signal level = 5
08200105BDB2C50469 Packettype = Security1 subtype = X10 security motion Sequence nbr = 5 id1-3 = BDB2C5 status = Motion battery level = OK Signal level = 6
08500106040100C879 Packettype = TEMP subtype = TEMP1 - THR128/138, THC138 channel 1 Sequence nbr = 6 ID = 1025 Temperature = 20 °C Signal level = 7 Battery = OK
08200107BDB2C50569 Packettype = Security1 subtype = X10 security motion Sequence nbr = 7 id1-3 = BDB2C5 status = No Motion battery level = OK Signal level = 6
08200108BDB2C50879 Packettype = Security1 subtype = X10 security motion Sequence nbr = 8 id1-3 = BDB2C5 status = Tamper battery level = OK Signal level = 7
Set Mode:0D 00 00 02 03 53 00 00 0F 7F 00 00 00 00
0D01000203531F000F7F00000000 Packettype = Interface Message subtype = Interface Response Sequence nbr = 2 response on cmnd = Set Mode Transceiver type = 433.92MHz Firmware version = 31 Undec off X10 enabled ARC enabled AC enabled HomeEasy EU enabled Ikea Koppla enabled Oregon Scientific enabled ATI enabled Visonic disabled Mertik enabled LightwaveRF enabled Hideki enabled La Crosse enabled FS20 disabled ProGuard disabled RFU protocol 7 disabled
08200100BDB2C50879 Packettype = Security1 subtype = X10 security motion Sequence nbr = 0 id1-3 = BDB2C5 status = Tamper battery level = OK Signal level = 7
063000080F0E70 Packettype = Remote control & IR subtype = ATI Remote Wonder Sequence nbr = 8 ID = 15 Command = 2Signal level = 7
New product don't work with current script.
sample log from RFXManager.
Stephane..
Reset receiver/transceiver:0D 00 00 00 00 00 00 00 00 00 00 00 00 00
Get Status:0D 00 00 01 02 00 00 00 00 00 00 00 00 00
0D01000102531F004F6F00000000 Packettype = Interface Message subtype = Interface Response Sequence nbr = 1 response on cmnd = Get Status Transceiver type = 433.92MHz Firmware version = 31 Undec off X10 enabled ARC enabled AC enabled HomeEasy EU enabled Ikea Koppla disabled Oregon Scientific enabled ATI enabled Visonic disabled Mertik enabled LightwaveRF enabled Hideki enabled La Crosse enabled FS20 disabled ProGuard disabled RFU protocol 7 disabled
08500100040100C879 Packettype = TEMP subtype = TEMP1 - THR128/138, THC138 channel 1 Sequence nbr = 0 ID = 1025 Temperature = 20 °C Signal level = 7 Battery = OK
0B110001004B949E0A000050 Packettype = Lighting2 subtype = AC Sequence nbr = 1 ID = 04B949E Unit = 10 Command = Off Signal level = 5
08500102040100C879 Packettype = TEMP subtype = TEMP1 - THR128/138, THC138 channel 1 Sequence nbr = 2 ID = 1025 Temperature = 20 °C Signal level = 7 Battery = OK
0B110003004B949E0A010F60 Packettype = Lighting2 subtype = AC Sequence nbr = 3 ID = 04B949E Unit = 10 Command = On Signal level = 6
0B110004004B949E0A010F50 Packettype = Lighting2 subtype = AC Sequence nbr = 4 ID = 04B949E Unit = 10 Command = On Signal level = 5
08200105BDB2C50469 Packettype = Security1 subtype = X10 security motion Sequence nbr = 5 id1-3 = BDB2C5 status = Motion battery level = OK Signal level = 6
08500106040100C879 Packettype = TEMP subtype = TEMP1 - THR128/138, THC138 channel 1 Sequence nbr = 6 ID = 1025 Temperature = 20 °C Signal level = 7 Battery = OK
08200107BDB2C50569 Packettype = Security1 subtype = X10 security motion Sequence nbr = 7 id1-3 = BDB2C5 status = No Motion battery level = OK Signal level = 6
08200108BDB2C50879 Packettype = Security1 subtype = X10 security motion Sequence nbr = 8 id1-3 = BDB2C5 status = Tamper battery level = OK Signal level = 7
Set Mode:0D 00 00 02 03 53 00 00 0F 7F 00 00 00 00
0D01000203531F000F7F00000000 Packettype = Interface Message subtype = Interface Response Sequence nbr = 2 response on cmnd = Set Mode Transceiver type = 433.92MHz Firmware version = 31 Undec off X10 enabled ARC enabled AC enabled HomeEasy EU enabled Ikea Koppla enabled Oregon Scientific enabled ATI enabled Visonic disabled Mertik enabled LightwaveRF enabled Hideki enabled La Crosse enabled FS20 disabled ProGuard disabled RFU protocol 7 disabled
08200100BDB2C50879 Packettype = Security1 subtype = X10 security motion Sequence nbr = 0 id1-3 = BDB2C5 status = Tamper battery level = OK Signal level = 7
063000080F0E70 Packettype = Remote control & IR subtype = ATI Remote Wonder Sequence nbr = 8 ID = 15 Command = 2Signal level = 7