can't read itron cl200 c1sr (fcc sk9c1a-3b) #297

Open fjleon1980 opened 4 months ago

fjleon1980 commented 4 months ago

thank you for this software. i can't seem to get a read on this electric type 7 meter itron cl200 c1sr (fcc sk9c1a-3b)

since you mention c1sr should work i'm wondering if not all c1sr are equal.

doing some searching i found "Operates using spread spectrum technology" so i wonder if it's a different protocol altogether.

this reddit post https://www.reddit.com/r/RTLSDR/comments/10fsj93/reading_itron_ert_scm_data_help although not for the same exact model suggests it may be transmitting using cellnet technology so I may be experiencing the same issue.

FCC https://fcc.io/SK9C1A-3B says this operates within 909.6 - 921.8 mhz. Is there anything I can do to confirm whether I am using rtlamr correctly? I am not passing any parameters to rtl_tcp or rtlamr

fjleon1980 commented 4 months ago

perhaps there is some hope. i used rtl_433 -f 912M and just saw my meter. I tried this yesterday but no luck. maybe it's not transmitting frequently?

model : SCMplus id : Protocol_ID: 0x1E Endpoint_Type: 0x07 Endpoint_ID: Consumption: 435272 (yesterday i took a picture of my meter and it said 04253, maybe right now it would say 04352?) Tamper : 0x0301 crc : 0x63D2 Meter_Type: Electric Integrity : CRC

model : IDM PacketTypeID: 0x1C PacketLength: 92 ApplicationVersion: 4 ERTType : 0x17 ERTSerialNumber: ConsumptionIntervalCount: 194 ModuleProgrammingState: 0xBC TamperCounters: 0x030100070D00 AsynchronousCounters: 0x00 PowerOutageFlags: 0x000000000000 LastConsumptionCount: 435272 DifferentialConsumptionIntervals: 3, 3, 4, 3, 6, 6, 7, 6, 6, 5, 7, 19, 23, 4, 5, 6, 6, 6, 5, 6, 3, 2, 4, 2, 4, 2, 4, 2,>TransmitTimeOffset: 3432 MeterIdCRC: 0x9631 PacketCRC : 0xCA63 Meter_Type: Electric Integrity : CRC

time : 2024-04-06 11:30:41 model : NETIDM PacketTypeID: 0x1C PacketLength: 92 ApplicationVersion: 4 ERTType : 0x17 ERTSerialNumber: ConsumptionIntervalCount: 194 ModuleProgrammingState: 0xBC TamperCounters: 0x030100070D00 Unknown_field_1: 0x00000000000000 LastGenerationCount: 6 Unknown_field_2: 0xA44801 LastConsumptionCount: -2134867920 DifferentialConsumptionIntervals: 3078, 224, 6156, 320, 14412, 2945, 40, 1539, 96, 2566, 96, 2056, 128, 8200, 512, 8208>TransmitTimeOffset: 3432 MeterIdCRC: 0x9631 PacketCRC : 0xCA63 MeterType : Electric

it transmitted twice between 4 minutes although didn't see any readings at the third set. is there any special parameter i should use with rtlamr or i just got lucky?