inconsistencies between text and table for channels.tsv for iEEG #817

Closed Remi-Gau closed 3 years ago

Remi-Gau commented 3 years ago

The text mentions:

The two required columns are channel name and type.

Whereas the table lists 5 required columns.

https://bids-specification.readthedocs.io/en/stable/04-modality-specific-files/04-intracranial-electroencephalography.html#channels-description-_channelstsv

Suggestion: removing the mention of required columns in the text and only rely on the table

Do the same for the EEG datatype (no inconsistency there but this is another duplication of the same information).

dorahermes commented 3 years ago

+1 on consistency with EEG and MEG: keep name, type and units as required