Open Jarewa opened 1 year ago
I'll answer it myself, maybe it will be useful to someone. PB7 There isn't pullup, that's why it floats because the sensors are too small pullup BLtouch/CRtouch. The solution to the problem was simple, just make a jumper in J40 (set J38 5V) jumper DC-PB7. It causes pullup 3.3V R187 on PB7.
The results now are very satisfactory
Is it only me who has this problem of poor design? optoisolation LE357C. In tests it receives
probe accuracy results: maximum 0.046484, minimum -0.431641, range 0.478125, average -0.148594, median -0.144531, standard deviation 0.147996
And it's not a mechanical fault or a damaged sensor, but a poorly designed optocoupler. Because if I use a different pin (PB7 - PG12), the results are fantastic.
How to repair to obtain good optocoupler times?