SKR 1.4 + TMC2209 UART + BTT Smart Filament Sensor = cut off the DIAG pin #466

Open jiberan1 opened 3 years ago

jiberan1 commented 3 years ago

For other user should be at least comment in documentation! Something like, when you using Motion Filament Detection with configuration SKR 1.4 + TMC2209 UART - BTT Smart Filament Sensor (or similar type) you need to cut off the DIAG pin on the driver so that the switch can work normally. FIL_RUNOUT_PIN P1_26 = cut off the DIAG pin on the driver E0

I spend last weak to searching what is wrong, why is motion not detected. After trying more version of Marlin (2.0.6, 2.0.7.2, last bugfix 2.0.8). Checking cabling, sensor, setting with FILAMENT_RUNOUT_SENSOR_DEBUG. Videos, documentation and nothing work. Only here I found the problem solution, cut off DIAG pin: https://www.reddit.com/r/BIGTREETECH/comments/icp6yb/btt_smart_filament_sensor_on_skr_14/g26fexh/