bigtreetech / BIGTREETECH-TouchScreenFirmware

support TFT35 V1.0/V1.1/V1.2/V2.0/V3.0, TFT28, TFT24 V1.1, TFT43, TFT50, TFT70
GNU General Public License v3.0
1.32k stars 1.65k forks source link

Hide the BED Icon #2943

Open eerthanaK opened 5 months ago

eerthanaK commented 5 months ago

Since I am using a chamber and not using a bed, I have disabled the bed temperature. Additionally, I need to remove or hide the bed icon from the BIGTREETECH TFT50 V3 display.

I am using Marlin software on the mainboard.

rondlh commented 4 months ago

That's good to know, thank you for the information.

zonalimitatore commented 4 months ago

Where you have disabled the HB? Just in Marlin config.h or also in TFT firmware (config.ini)?

Heated Bed Support Options: [disable: 0, enable: 1] heated_bed:0

eerthanaK commented 4 months ago

Where you have disabled the HB? Just in Marlin config.h or also in TFT firmware (config.ini)?

Heated Bed Support Options: [disable: 0, enable: 1] heated_bed:0

I disabled the heated bed in the marlin config. h and TFT firmware. But even then It is flashing from the heated bed and chamber in the display status screen

github-actions[bot] commented 2 months ago

This issue has been automatically marked as stale because it has had no activity for the last 60 days. It will be closed in 7 days if no further activity occurs. Thank you for your contribution.

eerthanaK commented 2 months ago

Good Morning Team, Already, I do the heated_bed: 0 is disabled in touch screen display. status screen is enabled but the chamber and bed icon is showing alternatively. If the status screen is disabled in chamber Icon only shown.

Regards & Thanks Keerthana T

On Thu, Jul 11, 2024 at 6:00 PM Zonalimitatore @.***> wrote:

Where you have disabled the HB? Just in Marlin config.h or also in TFT firmware (config.ini)? Heated Bed Support Options: [disable: 0, enable: 1]

heated_bed:0

— Reply to this email directly, view it on GitHub https://github.com/bigtreetech/BIGTREETECH-TouchScreenFirmware/issues/2943#issuecomment-2222811903, or unsubscribe https://github.com/notifications/unsubscribe-auth/A5AL5PYMFFKZKVW4LUHFQ4DZLZ3H3AVCNFSM6AAAAABJZMFAIKVHI2DSMVQWIX3LMV43OSLTON2WKQ3PNVWWK3TUHMZDEMRSHAYTCOJQGM . You are receiving this because you authored the thread.Message ID: @.*** .com>

NOVAXIM commented 1 month ago

I will join this postulate. I do not have a heated bed, but when I choose "Preheat" I have (Heat) "Both" and "Hotbed", instead of limiting the options to "Nozzle" only. On status screen "Bed" the tile is present but it is ok. Of course, I have disabled hotbed in Marlin and TFT configurations.