Trying to run Noctua 12V fans off the PWM pins, but the fans never kick on. 12v jumpers are correctly installed. I had success with the Manta M8P V1.1, but not on the V2.0. I am getting the following error from Klipper:

"MCU 'mcu' shutdown: Not a valid PWM pin"

My fan config:

[fan_generic exhaust] pin: PC1 max_power: 1.0 shutdown_speed: 1.0 kick_start_time: 0.5 tachometer_pin: PA2 hardware_pwm: True cycle_time: 0.00004 # 25 kHz

If I turned hardware_pwm to "false", the klipper error goes away but the fan still doesn't run. Per the documentation, PWM fans should be pin PC1 and PC2.

mrstone14 commented 8 months ago

Figured out the problem:

The PWM pins and Tachometer pins on the V2 pinout jpeg are reversed. When viewing the 3D file provided by BTT, you can see the pins labeled on the bottom of the PCB, which are swapped compared to the jpeg file. I have reversed the pins in my Klipper config and all is working.

This appears to be the case for Fan 4, Fan 5 and Fan 6. I have confirmed this is working for Fan 5 and Fan 6, but have not tested Fan 4.

Posting photos to help anyone else. Suggested Klipper config:

FAN 4 (not confirmed) pin: PA4

FAN 5 (confirmed) pin: PA6 tachometer_pin: PC2

FAN 6 (confirmed) pin: PA2 tachometer_pin: PC1

BIGTREETECH MANTA M8P V2 0 PinOut

Screenshot 2024-01-10 083259__

jurassicplayer commented 8 months ago

Could probably leave this issue open, since it's still an issue with their documentation (threw me for a loop too xD).