Incorrect object re-cycling and re-use vulnerability in Apache Tomcat. Incorrect recycling of the request and response used by HTTP/2 requests
could lead to request and/or response mix-up between users.
This issue affects Apache Tomcat: from 11.0.0-M23 through 11.0.0-M26, from 10.1.27 through 10.1.30, from 9.0.92 through 9.0.95.
Users are recommended to upgrade to version 11.0.0, 10.1.31 or 9.0.96, which fixes the issue.
CVE-2024-52317 - Medium Severity Vulnerability
Vulnerable Library - tomcat-embed-core-9.0.37.jar
Core Tomcat implementation
Library home page: https://tomcat.apache.org/
Path to dependency file: /poweriq-worker/pom.xml
Path to vulnerable library: /home/wss-scanner/.m2/repository/org/apache/tomcat/embed/tomcat-embed-core/9.0.37/tomcat-embed-core-9.0.37.jar
Dependency Hierarchy: - :x: **tomcat-embed-core-9.0.37.jar** (Vulnerable Library)
Found in HEAD commit: dd01a1d4381c7a3b94ba25748c015a094c33088e
Found in base branch: master
Vulnerability Details
Incorrect object re-cycling and re-use vulnerability in Apache Tomcat. Incorrect recycling of the request and response used by HTTP/2 requests could lead to request and/or response mix-up between users. This issue affects Apache Tomcat: from 11.0.0-M23 through 11.0.0-M26, from 10.1.27 through 10.1.30, from 9.0.92 through 9.0.95. Users are recommended to upgrade to version 11.0.0, 10.1.31 or 9.0.96, which fixes the issue.
Publish Date: 2024-11-18
URL: CVE-2024-52317
CVSS 3 Score Details (6.5)
Base Score Metrics: - Exploitability Metrics: - Attack Vector: Network - Attack Complexity: Low - Privileges Required: None - User Interaction: None - Scope: Unchanged - Impact Metrics: - Confidentiality Impact: Low - Integrity Impact: Low - Availability Impact: None
For more information on CVSS3 Scores, click here.Suggested Fix
Type: Upgrade version
Origin: https://tomcat.apache.org/security-11.html
Release Date: 2024-11-18
Fix Resolution: 9.0.96