binsentsu / home-assistant-solaredge-modbus

Home assistant Component for reading data locally from Solaredge inverter through modbus TCP
295 stars 71 forks source link

[Errno 111] Connection refused #213

Open philippegabert opened 1 year ago

philippegabert commented 1 year ago

Hi,

I have been using the integration for quite some time and it works but I always have had some ERROR in the logs. My refresh rate is 1sec. I have the latest version installed (1.10.1).

2023-11-24 15:22:21.407 WARNING (MainThread) [custom_components.solaredge_modbus] not able to connect to 192.168.4.67:1502
2023-11-24 15:22:24.437 ERROR (MainThread) [pymodbus.logging] Connection to (192.168.4.67, 1502) failed: timed out
2023-11-24 15:22:24.437 WARNING (MainThread) [custom_components.solaredge_modbus] not able to connect to 192.168.4.67:1502
2023-11-24 15:22:26.297 ERROR (MainThread) [pymodbus.logging] Connection to (192.168.4.67, 1502) failed: [Errno 111] Connection refused
2023-11-24 15:22:26.298 WARNING (MainThread) [custom_components.solaredge_modbus] not able to connect to 192.168.4.67:1502
2023-11-24 15:22:26.334 ERROR (MainThread) [pymodbus.logging] Connection to (192.168.4.67, 1502) failed: [Errno 111] Connection refused

and also:

2023-11-24 15:26:21.314 ERROR (MainThread) [custom_components.solaredge_modbus] Error reading modbus data
Traceback (most recent call last):
  File "/config/custom_components/solaredge_modbus/__init__.py", line 232, in async_refresh_modbus_data
    update_result = self.read_modbus_data()
                    ^^^^^^^^^^^^^^^^^^^^^^^
  File "/config/custom_components/solaredge_modbus/__init__.py", line 309, in read_modbus_data
    and self.read_modbus_data_meter1()
        ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
  File "/config/custom_components/solaredge_modbus/__init__.py", line 319, in read_modbus_data_meter1
    return self.read_modbus_data_meter("m1_", 40190)
           ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
  File "/config/custom_components/solaredge_modbus/__init__.py", line 334, in read_modbus_data_meter
    meter_data = self.read_holding_registers(
                 ^^^^^^^^^^^^^^^^^^^^^^^^^^^^
  File "/config/custom_components/solaredge_modbus/__init__.py", line 291, in read_holding_registers
    return self._client.read_holding_registers(
           ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
  File "/usr/local/lib/python3.11/site-packages/pymodbus/client/mixin.py", line 102, in read_holding_registers
    return self.execute(
           ^^^^^^^^^^^^^
  File "/usr/local/lib/python3.11/site-packages/pymodbus/client/base.py", line 179, in execute
    raise ConnectionException(f"Failed to connect[{self!s}]")
pymodbus.exceptions.ConnectionException: Modbus Error: [Connection] Failed to connect[ModbusTcpClient(192.168.4.67:1502)]
2023-11-24 15:26:21.357 ERROR (MainThread) [pymodbus.logging] Connection to (192.168.4.67, 1502) failed: [Errno 111] Connection refused

Is there anyway to get rid of those errors? As mentioned, the integration works and I do get the data... so I don't know why the integration keeps on throwing those errors.

Thanks

ChristophCaina commented 1 year ago

Connection refused means, that the inverter actively rejected the connection request. I don't beleive, that this is something that can be fixed within the integration - at least, as long as we don't know when exactly this happens...

Is the Inverter in Sleep Mode (Night mode) when it refuses the connection request? According to the time from the logs, I don't beleive so...

Also, the Software Version of the Inverter could be relevant... But these are not provided by the Modbus Integration (AFAIK)...

only with the Core-Integration (which connects to the web api) you will get the information as Attribute of the "inverters" sensor...

dsp1Version: 1.13.2016 dsp2Version: 2.19.1601 cpuVersion: 4.16.25

I would also get in contact with the SolarEdge support, to check, if this might be a firmware issue - or if this might already be fixed with a newer firmware that needs to be installed on the inverter.

philippegabert commented 11 months ago

Thanks @ChristophCaina. Question though: It looks to me that it's normal that the inverter refuses the connection as you can only have active. But... why does the integration tries to connect to the inverter? I assume (but may be wrong) that the "Connection refused" is for "new" connections to the inverter... In the case you have short update frequencies (1 second) and short timeout, the integration should be able to reuse existing connections and therefore not throw those kind of errors?

legantois commented 8 months ago

184

Still getting same issue regularly; there should be a way to handle this

2024-03-17 06:43:38.493 ERROR (SyncWorker_31) [custom_components.solaredge_modbus] Error reading modbus data Traceback (most recent call last): File "/config/custom_components/solaredge_modbus/init.py", line 247, in _refresh_modbus_data update_result = self.read_modbus_data() ^^^^^^^^^^^^^^^^^^^^^^^ File "/config/custom_components/solaredge_modbus/init.py", line 321, in read_modbus_data self.read_modbus_data_inverter() File "/config/custom_components/solaredge_modbus/init.py", line 608, in read_modbus_data_inverter inverter_data = self.read_holding_registers( ^^^^^^^^^^^^^^^^^^^^^^^^^^^^ File "/config/custom_components/solaredge_modbus/init.py", line 305, in read_holding_registers return self._client.read_holding_registers( ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ File "/usr/local/lib/python3.12/site-packages/pymodbus/client/mixin.py", line 102, in read_holding_registers return self.execute( ^^^^^^^^^^^^^ File "/usr/local/lib/python3.12/site-packages/pymodbus/client/base.py", line 177, in execute return self.transaction.execute(request) ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ File "/usr/local/lib/python3.12/site-packages/pymodbus/transaction.py", line 168, in execute response, last_exception = self._transact( ^^^^^^^^^^^^^^^ File "/usr/local/lib/python3.12/site-packages/pymodbus/transaction.py", line 313, in _transact result = self._recv(response_length, full) ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ File "/usr/local/lib/python3.12/site-packages/pymodbus/transaction.py", line 343, in _recv read_min = self.client.framer.recvPacket(min_size) ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ File "/usr/local/lib/python3.12/site-packages/pymodbus/framer/base.py", line 77, in recvPacket return self.client.recv(size) ^^^^^^^^^^^^^^^^^^^^^^ File "/usr/local/lib/python3.12/site-packages/pymodbus/client/tcp.py", line 210, in recv return self._handle_abrupt_socket_close( ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ File "/usr/local/lib/python3.12/site-packages/pymodbus/client/tcp.py", line 257, in _handle_abrupt_socket_close raise ConnectionException(msg) pymodbus.exceptions.ConnectionException: Modbus Error: [Connection] ModbusTcpClient(192.168.178.61:1502): Connection unexpectedly closed 2.1696090698242188e-05 seconds into read of 8 bytes without response from slave before it closed connection 2024-03-17 06:44:10.546 ERROR (SyncWorker_51) [pymodbus.logging] Connection to (192.168.178.61, 1502) failed: [Errno 111] Connection refused 2024-03-17 06:44:10.547 WARNING (SyncWorker_51) [custom_components.solaredge_modbus] not able to connect to 192.168.178.61:1502

My config

jwindley commented 6 months ago

I have the same issue. Any update on this please?

K-Raymer commented 6 months ago

Also getting the same issue. 30 second pole int.

willembargeman commented 5 months ago

Experienced the same kind of issue. Noticed that HA was not able to reach the SolarEdge inverter. In the log files I see the following.

ERROR (MainThread) [pymodbus.client.tcp] Connection to (10.27.11.9, 1502) failed: timed out

Created packet capture on the network and noticed that the inverter was not responding to the TCP SYN request. After some additional testing I found a interesting behaviour.

The inverter was drop all incoming requests from the same subnet. In my example, the inverter and HA are both placed in the subnet 10.27.11.0/24. (so 10.27.11.0-10.27.11.255). Even ping traffic is dropped.

With my laptop I was able to ping the inverter and also got a SYN ACK when using NMAP on port 1502. My laptop was in a different segment (10.27.10.0/24).

Workaround is by placing HA and the inverter in a different subnet or by using NAT (which is more complex).

Doc-Jump commented 3 weeks ago

Same here, Integration suddenly stopped working, aswell SolarEdge Modbus and also SolarEdge Modbus Multi integration. Tried to disable and enable the TCP Modbus setting in the inverter's interface, doesn't help. I also think it must have to do something with the converter instead of the integration as the inverter can be reached over network but refuses connection on the Modbus-Port. Did anyone contact SolarEdge's support?

Doc-Jump commented 2 weeks ago

Dear all,

Had contact with Solaredge support. They remotely installed a newer firmware on the inverter. Since then it has been running smoothly again. Simply report it there with the reference to error code 111 and that no data can be accessed via the Modbus.

In my opinion, this issue could be closed, as it seems to be a Software Problem on the inverter.