Hello and thanks for this great integration!
I suggest to integrate also this kind of informations in this Solaredge HA integration:
battery stored energy (how many kWh are present in battery):
“BattEnergy” = (‘soe’*’available_energy’) /100 (kWh)
Home power instantaneous imported/exporter/auto consumption:
If meter ‘power’ < 0
Imported= meter power * -1
Exported = 0
Else:
Exported = meter ‘power’
Imported = 0
If meter ‘power’ <=0:
Auto_consumption = inverter ‘power_ac’
Else:
Auto_consumption = inverter ‘power_ac’ – meter ‘power’
If autoconsumption < 0:
Autoconsumption = 0
Power only from FV when battery is present:
FVpower = inverter_'power_ac' + battery 'instantaneouspower'
if FVpower >0:
FVpower = inverter'power_ac' + battery 'instantaneous_power'
else:
FVpower = 0
Home Total Consumption
Home_Total_Consumption =inverter 'power_ac' – meter 'power’
Hello and thanks for this great integration! I suggest to integrate also this kind of informations in this Solaredge HA integration:
battery stored energy (how many kWh are present in battery): “BattEnergy” = (‘soe’*’available_energy’) /100 (kWh)
Home power instantaneous imported/exporter/auto consumption: If meter ‘power’ < 0 Imported= meter power * -1
Exported = 0 Else: Exported = meter ‘power’ Imported = 0
If meter ‘power’ <=0: Auto_consumption = inverter ‘power_ac’ Else: Auto_consumption = inverter ‘power_ac’ – meter ‘power’
If autoconsumption < 0: Autoconsumption = 0
Power only from FV when battery is present: FVpower = inverter_'power_ac' + battery 'instantaneouspower' if FVpower >0: FVpower = inverter'power_ac' + battery 'instantaneous_power' else: FVpower = 0
Home Total Consumption Home_Total_Consumption =inverter 'power_ac' – meter 'power’