"One ME preview source from variables"

I've been playing with this feedback a lot lately. Is it expected that the M/E field that is supposed to support variables is only working with M/E 1 ?

I've created a variable that contains the number of a specific M/E (1 is for M/E1, 2 is for M/E2 , etc.) But it seems that field is only working with "1" (through designed and specific variable or direct input number). When the variable is "2", the feedback returns nothing. Is this correct ?

Thank you in advance for your reply on this matter.

davidjoshuaford commented 6 months ago

Is ME2 also set to the same input as ME1 was?

LYMPIA commented 6 months ago

Yes It was. But problem is solved with a reboot of the software... It's working now as expected.