Acer PL6510 Projector doesnt work #59

Closed metalmatze74 closed 1 year ago

metalmatze74 commented 1 year ago

Hello, I tried to connect an Acer PL6510, but it only shows OK on the connection, but the variables are empty and the beamer dont respond to any command. I tried PJLinkTest from the https://pjlink.jbmia.or.jp/ and the projector responded as expected.

If I press GET ALL on the PJLinkTest program I get: [2023.05.02 11:29:53.607] Connected!!! [2023.05.02 11:29:53.625] RECV:pjlink 0

[2023.05.02 11:29:53.628] SEND:%1POWR ?

[2023.05.02 11:29:53.645] RECV:%1powr=1

[2023.05.02 11:29:53.647] Closed!!!(Disconnect) [2023.05.02 11:29:53.650] Connected!!! [2023.05.02 11:29:53.655] RECV:pjlink 0

[2023.05.02 11:29:53.658] SEND:%1INPT ?

[2023.05.02 11:29:53.677] RECV:%1inpt=31

[2023.05.02 11:29:53.681] Closed!!!(Disconnect) [2023.05.02 11:29:53.685] Connected!!! [2023.05.02 11:29:53.695] RECV:pjlink 0

[2023.05.02 11:29:53.699] SEND:%1AVMT ?

[2023.05.02 11:29:53.715] RECV:%1avmt=30

[2023.05.02 11:29:53.718] Closed!!!(Disconnect) [2023.05.02 11:29:53.721] Connected!!! [2023.05.02 11:29:53.725] RECV:pjlink 0

[2023.05.02 11:29:53.729] SEND:%1ERST ?

[2023.05.02 11:29:53.745] RECV:%1erst=000000

[2023.05.02 11:29:53.753] Closed!!!(Disconnect) [2023.05.02 11:29:53.757] Connected!!! [2023.05.02 11:29:53.765] RECV:pjlink 0

[2023.05.02 11:29:53.769] SEND:%1LAMP ?

[2023.05.02 11:29:53.785] RECV:%1lamp=470 1

[2023.05.02 11:29:53.789] Closed!!!(Disconnect) [2023.05.02 11:29:53.792] Connected!!! [2023.05.02 11:29:53.795] RECV:pjlink 0

[2023.05.02 11:29:53.799] SEND:%1INST ?

[2023.05.02 11:29:53.815] RECV:%1inst=11 12 21 22 31 32

[2023.05.02 11:29:53.819] Closed!!!(Disconnect) [2023.05.02 11:29:53.825] Connected!!! [2023.05.02 11:29:53.835] RECV:pjlink 0

[2023.05.02 11:29:53.838] SEND:%1NAME ?

[2023.05.02 11:29:53.856] RECV:%1name=Acer 1080P PJ

[2023.05.02 11:29:53.858] 41 63 65 72 20 31 30 38 30 50 20 50 4A [2023.05.02 11:29:53.861] Closed!!!(Disconnect) [2023.05.02 11:29:53.864] Connected!!! [2023.05.02 11:29:53.866] RECV:pjlink 0

[2023.05.02 11:29:53.870] SEND:%1INFO ?

[2023.05.02 11:29:53.886] RECV:%1info=1080P PJ

[2023.05.02 11:29:53.889] Closed!!!(Disconnect) [2023.05.02 11:29:53.893] Connected!!! [2023.05.02 11:29:53.905] RECV:pjlink 0

[2023.05.02 11:29:53.908] SEND:%1INF1 ?

[2023.05.02 11:29:53.926] RECV:%1inf1=Acer

[2023.05.02 11:29:53.928] Closed!!!(Disconnect) [2023.05.02 11:29:53.931] Connected!!! [2023.05.02 11:29:53.935] RECV:pjlink 0

[2023.05.02 11:29:53.937] SEND:%1INF2 ?

[2023.05.02 11:29:53.956] RECV:%1inf2=Acer 1080P PJ

[2023.05.02 11:29:53.958] Closed!!!(Disconnect) [2023.05.02 11:29:53.961] Connected!!! [2023.05.02 11:29:53.975] RECV:pjlink 0

[2023.05.02 11:29:53.979] SEND:%1CLSS ?

[2023.05.02 11:29:53.995] RECV:%1clss=2

[2023.05.02 11:29:53.997] Closed!!!(Disconnect)

istnv commented 1 year ago

Which version of companion? The module in V3.0 has a lot of improvements over the 2.4 version.

metalmatze74 commented 1 year ago

I use 2.4 because 3 is beta. I've tested with version 3, but with the same result.

istnv commented 1 year ago

According to the log you posted, that projector is sending lower case responses. The protocol does not really specify and the vast majority of projectors encountered respond with uppercase. An earlier issue was the module sent lower case, yet some projectors would respond only when the queries are uppercase. There is no workaround until the module is updated to accommodate a lower case response.

istnv commented 1 year ago

@metalmatze74 This should be fixed in the latest v3.0 build. V3.0 is close to release and v2.4 is not receiving updates anymore.