Double rolling regression for the gradient approach #9

Open bjartelund opened 4 years ago

bjartelund commented 4 years ago

Reversing the dataframe for rolling regression can give velocities for lower temperatures in addition to the high temperatures. The deviations between these points could be a diagnostic measure of how well the gradient approach works.

bjartelund commented 4 years ago

10 partially solves this, but does not feature any direct diagnostics