Closed Gary-Manuel closed 3 days ago
I am able to set battery power reserve to 100% on my HY5.0, what model do you have and what f/w?
Hi. Just checked again and it's the same. Can set to 99% but not 100% from both HA and the portal. Same on both inverters. 2 x HY3.6 Gen2 on v909 with a single 9.5kWh battery on each running v3012.
From: britkat1980 @.> Sent: 28 June 2023 18:49 To: britkat1980/giv_tcp @.> Cc: Gary-Manuel @.>; Author @.> Subject: Re: [britkat1980/giv_tcp] Eco(Paused) not working (Issue #64)
I am able to set battery power reserve to 100% on my HY5.0, what model do you have and what f/w?
— Reply to this email directly, view it on GitHubhttps://github.com/britkat1980/giv_tcp/issues/64#issuecomment-1611913020, or unsubscribehttps://github.com/notifications/unsubscribe-auth/AN7SBD2AJPHOOAOYIZWAB3DXNR4CLANCNFSM6AAAAAAZQCPZ7I. You are receiving this because you authored the thread.Message ID: @.***>
Ok, perhaps this is a Gen2 thing? I’ll check with the GE team
Thank you.
I believe that Eco(Paused) just sets Battery Power Reserve to 100% in order to disable discharge. It would appear though, that 100% is not a valid setting for Battery Power Reserve, either from HA or from the portal. 99% is however a valid setting and it is suggested that GivTCP could use this instead of 100%.