I use Kubuntu Plasma 14.04 Trusty kernel 3.13.0.161

I think Conky ( version 1.9 ) not execute commands line type " ${if_match ${hwmon 1 fan 1} < 1000} " and this activate zenity or kdialog pop up every time.

How solved this problem ?

My .conkyrc script:

# Conky, a system monitor, based on torsmo
#
# Any original torsmo code is licensed under the BSD license
#
# All code written since the fork of torsmo is licensed under the GPL
#
# Please see COPYING for details
#
# Copyright (c) 2004, Hannu Saransaari and Lauri Hakkarainen
# Copyright (c) 2005-2010 Brenden Matthews, Philip Kovacs, et. al. (see AUTHORS)
# All rights reserved.
#
# This program is free software: you can redistribute it and/or modify
# it under the terms of the GNU General Public License as published by
# the Free Software Foundation, either version 3 of the License, or
# (at your option) any later version.
#
# This program is distributed in the hope that it will be useful,
# but WITHOUT ANY WARRANTY; without even the implied warranty of
# MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.  See the
# GNU General Public License for more details.
# You should have received a copy of the GNU General Public License
# along with this program.  If not, see <http://www.gnu.org/licenses/>.
#

alignment no
background no
border_width 1
cpu_avg_samples 2
default_color white
default_outline_color white
default_shade_color white
draw_borders no
draw_graph_borders yes
draw_outline no
draw_shades no
use_xft yes
xftfont DejaVu Sans Mono:size=10
gap_x 720
gap_y 60
minimum_size 5 5
net_avg_samples 2
no_buffers yes
double_buffer yes
out_to_console no
out_to_stderr no
extra_newline no
own_window yes
own_window_class Conky
own_window_type normal
own_window_transparent yes
own_window_argb_visual yes
own_window_argb_value 0
own_window_hints undecorated,below,sticky,skip_taskbar,skip_pager
stippled_borders 0
update_interval 1.0
uppercase no
use_spacer none
show_graph_scale no
show_graph_range no

TEXT
           ${color white}Conky - System Monitor
$hr
${color green}Uptime:${color green} $uptime
${color white}Frequency (in MHz):$color $freq
${color white}Frequency (in GHz):$color $freq_g
${color green}RAM:${color green} $mem / $memeasyfree / $memfree / $memmax
${color white}Swap:$color $swap/$swapmax - $swapperc% ${color yellow} ${swapbar 4}
${color white}CPU Usage:$cpu% ${color yellow} ${cpubar 4}
${color white}CPU Fan:$color ${exec sensors | awk '/fan1/ { print $2 }'}rpm ${if_match ${hwmon 1 fan 1} < 1000} ${exec zenity --warning --text "Rotação CPU Fan abaixo do normal"} ${endif} Chassis Fan:$color ${exec sensors | awk '/fan2/ { print $2 }'}rpm  ${if_match ${hwmon 1 fan 2} < 1000} ${exec zenity --warning --text "Rotação Chassis Fan abaixo do normal"} ${endif}
$hr
${color white}UPS APC BE600N-BR: 
Charge:$color ${apcupsd localhost 3551} ${apcupsd_charge}%  Load:${apcupsd_load}% ${if_match ${apcupsd_load} > 50} ${exec zenity --warning --text "Consumo do PC acima de 50% do Nobreak"} ${endif} ${color yellow} ${apcupsd_loadbar 4}
${color white}Inp Volt: ${apcupsd_linev}V   Time Left: ${apcupsd_timeleft}min
Reason: ${apcupsd_lastxfer}
$hr
${color green}Voltages: 
Vcore:${exec sensors | awk '/in0/ {print $2}'}V ${if_match ${hwmon 1 vol 0} < 1} ${exec zenity --warning --text "Tensão Vcore abaixo do normal"} ${endif} ${if_match ${hwmon 1 vol 0} > 1} ${exec zenity --warning --text "Tensão Vcore acima do normal"} ${endif} NB:${exec sensors | awk '/in1/ {print $2}'}V   ${if_match ${hwmon 1 vol 1} < 1} ${exec zenity --warning --text "Tensão NB abaixo do normal"} ${endif}  ${if_match ${hwmon 1 vol 1} > 1} ${exec zenity --warning --text "Tensão NB acima do normal"} ${endif} +3,3V:${exec sensors | awk '/in2/ {print $2}'}V  ${if_match ${hwmon 1 vol 2} < 3} ${exec zenity --warning --text "Tensão +3,3V abaixo do normal"} ${endif} ${if_match ${hwmon 1 vol 2} > 3} ${exec zenity --warning --text "Tensão +3,3V acima do normal"} ${endif} 
+5,0V:${exec sensors | awk '/in3/ {print $2}'}V ${if_match ${hwmon 1 vol 3} < 3} ${exec zenity --warning --text "Tensão +5,0V abaixo do normal"} ${endif} ${if_match ${hwmon 1 vol 3} > 3} ${exec zenity --warning --text "Tensão +5,0V acima do normal"} ${endif} +12,0V:${exec sensors | awk '/in4/ {print $2}'}V ${if_match ${hwmon 1 vol 4} < 3} ${exec zenity --warning --text "Tensão +12,0V abaixo do normal"} ${endif} ${if_match ${hwmon 1 vol 4} > 3} ${exec zenity --warning --text "Tensão +12,0V acima do normal"} ${endif} DRAM:${exec sensors | awk '/in5/ {print $2}'}V ${if_match ${hwmon 1 vol 5} < 1} ${exec zenity --warning --text "Tensão DRAM abaixo do normal"} ${endif} ${if_match ${hwmon 1 vol 5} > 2} ${exec zenity --warning --text "Tensão DRAM acima do normal"} ${endif}
LDT:${exec sensors | awk '/in6/ {print $2}'}V ${if_match ${hwmon 1 vol 6} < 1} ${exec zenity --warning --text "Tensão LDT abaixo do normal"} ${endif} ${if_match ${hwmon 1 vol 6} > 1} ${exec zenity --warning --text "Tensão LDT acima do normal"} ${endif}   3VSB:${exec sensors | awk '/in7/ {print $2}'}V  ${if_match ${hwmon 1 vol 7} < 2} ${exec zenity --warning --text "Tensão 3VSB abaixo do normal"} ${endif} ${if_match ${hwmon 1 vol 7} > 3} ${exec zenity --warning --text "Tensão 3VSB acima do normal"} ${endif}  Vbat:${exec sensors | awk '/Vbat/ {print $2}'}V ${if_match ${hwmon 1 vol 8} < 3} ${exec zenity --warning --text "Tensão Vbat abaixo do normal"} ${endif} ${if_match ${hwmon 1 vol 8} > 3} ${exec zenity --warning --text "Tensão Vbat acima do normal"} ${endif}
${color white}$hr
${color white}Temperatures:
CPU:$color ${hwmon 1 temp 1}°C ${if_match ${hwmon 1 temp 1} > 68} ${exec zenity --warning --text "Temperatura do processador acima de 68ºC"} ${endif}   NB:${hwmon 1 temp 2}°C   SB:${hwmon 1 temp 3}°C
HDD:$color ${execi 5 hddtemp /dev/sda} 
$hr
${color white}File systems:
$color ${fs_used /}/ ${fs_size /} ${color yellow} ${fs_bar 4 /}
${color white}Networking:
Up:$color ${upspeed eth0} ${color white} - Down:$color ${downspeed eth0}
$hr
${color white}Name               PID    CPU%   MEM%
${color white} ${top name 1} ${top pid 1} ${top cpu 1} ${top mem 1} 
${color white} ${top name 2} ${top pid 2} ${top cpu 2} ${top mem 2}
${color white} ${top name 3} ${top pid 3} ${top cpu 3} ${top mem 3}
${color white} ${top name 4} ${top pid 4} ${top cpu 4} ${top mem 4}
lasers commented 6 years ago

Duplicate https://github.com/brndnmtthws/conky/issues/334. \o/

jh1234567890 commented 6 years ago

Hi, I solved it yesterday night.

I executed these commands in root terminal:

chown root:root /usr/bin/conky

chmod +s /usr/bin/conky

Now conky is fine after boot, thanks !!!

lasers commented 6 years ago

Interesting. We will have to try that someday. I guess I will close this now. Thanks. :-)

jh1234567890 commented 6 years ago

Hi, the problem return before update kernel system.

I solved it after remove " conky all " and install " conky ci " and remove again and reinstall again " conky all " ... uufff !!!

Is very hard ...

Please develloper, fix this bug !!!

Thanks !!!

jh1234567890 commented 5 years ago

Hello everybody ...

I return this question because the problem back some time when update the old Kubuntu 14.04 trusty but it solve itself after reboot.the system.

Thanks all.

lasers commented 5 years ago

The issue hadn't been worked on. My suggestion is to use notify-send instead of zenity so you don't have to click anything at every popup. I also don't know how conky behaves when zenity does not finish its operation (ie leaving a dialog open for some time).

EDIT: The documentation says all object gets created and destroyed at every interval.