DRC detecting PTH-parts with just one copper-site #2801

Closed GoogleCodeExporter closed 9 years ago

GoogleCodeExporter commented 9 years ago
in some cases we get sketches with old or broken pth-parts. these parts have 
just one coppersite in the svg. so if the gerber gets exported they produce a 
short with the automatically created copperfill from the 
pcb-production-inscriper. 

the problem is that this gets not detected and don't show up as a "bug" in the 
panelizer-output-file. 

an example is the file "53807694" from fab-order 000085

Original issue reported on code.google.com by bluearc....@gmail.com on 10 Dec 2013 at 1:13

GoogleCodeExporter commented 9 years ago
rb835f5903f05

definitely catching the example case correctly, but I am not sure whether it 
will find everything.

Original comment by irasc...@gmail.com on 11 Dec 2013 at 5:29

GoogleCodeExporter commented 9 years ago
add this to the normal (user) drc if possible.

Original comment by irasc...@gmail.com on 15 Dec 2013 at 7:27

GoogleCodeExporter commented 9 years ago
rfd68d6afa953 addresses comment 2. Seems to work fine in the sample case. 
Leaving as partly done until it's tested further.

Original comment by irasc...@gmail.com on 19 Dec 2013 at 2:05

GoogleCodeExporter commented 9 years ago
Issue has moved to new issue tracker at github. Please continue the discussion 
at https://github.com/fritzing/fritzing-app/issues