[network::cisco::standard::snmp::plugin] --mode=environment - thresholds ignored #4276

Open joschi99 opened 1 year ago

joschi99 commented 1 year ago

The warning on Temp: Inlet_A' and Sensor 'Temp: Inlet_A/1018' are not correct. As you can see the threshold are ~:70

Why we have this warning?

Also setting a new warning threshold like --warning='temperature,1018,80' will show still same error.

./centreon_plugins.pl --hostname=x.x.x.x --snmp-community='public' --snmp-version=2c  --plugin=network::cisco::standard::snmp::plugin --mode=environment --component='' --filter='' --threshold-overload='' --warning='' --critical='' --filter='' --verbose
WARNING: Temperature 'Switch 1 Slot 1 Temp: Inlet_A' status is warning - Sensor 'Temp: Inlet_A/1018' is 47 C | 'temp_Switch 1 Slot 1 Temp: Outlet_A'=45C;;~:80;; 'temp_Switch 1 Slot 1 Temp: Outlet_B'=41C;;~:75;; 'temp_Switch 1 Slot 1 Temp: Inlet_A'=47C;;~:70;; 'temp_Switch 1 Slot 1 Temp: Inlet_B'=44C;;~:70;; 'temp_Switch 1 Slot 1 Temp: UADP_0_0'=53C;;~:124;; 'temp_Switch 1 Slot 1 Temp: UADP_0_1'=55C;;~:124;; 'temp_Switch 1 Slot 1 Temp: UADP_0_2'=55C;;~:124;; 'temp_Switch 1 Slot 1 Temp: UADP_0_3'=55C;;~:124;; 'temp_Switch 1 Slot 1 Temp: UADP_0_4'=54C;;~:124;; 'temp_Switch 1 Slot 1 Temp: UADP_0_5'=53C;;~:124;; 'temp_Switch 1 Slot 1 Temp: UADP_0_6'=53C;;~:124;; 'temp_Switch 1 Slot 1 Temp: UADP_0_7'=56C;;~:124;; 'temp_Switch 1 Slot 1 Temp: UADP_0_8'=55C;;~:124;; 'temp_Switch 1 Slot 1 Temp: Coretemp'=50C;;~:125;; 'temp_Switch 1 Slot 1 Temp: OutletDB'=44C;;~:85;; 'temp_Switch 2 Slot 1 Temp: Outlet_A'=44C;;~:80;; 'temp_Switch 2 Slot 1 Temp: Outlet_B'=40C;;~:75;; 'temp_Switch 2 Slot 1 Temp: Inlet_A'=44C;;~:70;; 'temp_Switch 2 Slot 1 Temp: Inlet_B'=43C;;~:70;; 'temp_Switch 2 Slot 1 Temp: UADP_0_0'=57C;;~:124;; 'temp_Switch 2 Slot 1 Temp: UADP_0_1'=57C;;~:124;; 'temp_Switch 2 Slot 1 Temp: UADP_0_2'=57C;;~:124;; 'temp_Switch 2 Slot 1 Temp: UADP_0_3'=57C;;~:124;; 'temp_Switch 2 Slot 1 Temp: UADP_0_4'=58C;;~:124;; 'temp_Switch 2 Slot 1 Temp: UADP_0_5'=57C;;~:124;; 'temp_Switch 2 Slot 1 Temp: UADP_0_6'=55C;;~:124;; 'temp_Switch 2 Slot 1 Temp: UADP_0_7'=58C;;~:124;; 'temp_Switch 2 Slot 1 Temp: UADP_0_8'=57C;;~:124;; 'temp_Switch 2 Slot 1 Temp: Coretemp'=50C;;~:125;; 'temp_Switch 2 Slot 1 Temp: OutletDB'=43C;;~:85;; 'sensor.voltsDC_PSOC-MB_0: VOUT'=12.067V;;;; 'sensor.voltsDC_PSOC-MB_1: VOUT'=3.3V;;;; 'sensor.voltsDC_PSOC-MB_2: VOUT'=12.079V;;;; 'sensor.voltsDC_PSOC-MB_3: VOUT'=6.967V;;;; 'sensor.voltsDC_PSOC-MB_4: VOUT'=5V;;;; 'sensor.voltsDC_PSOC-MB_5: VOUT'=3.298V;;;; 'sensor.voltsDC_PSOC-MB_7: VOUT'=2.501V;;;; 'sensor.voltsDC_PSOC-MB_8: VOUT'=1.8V;;;; 'sensor.voltsDC_PSOC-MB_9: VOUT'=1.499V;;;; 'sensor.voltsDC_PSOC-MB_10: VOU'=1.2V;;;; 'sensor.voltsDC_3570MB1_0: VOUT'=1V;;;; 'sensor.voltsDC_3570MB2_0: VOUT'=1V;;;; 'sensor.voltsDC_3570MB3_0: VOUT'=1.651V;;;; 'sensor.voltsDC_35215MB1_0: VOU'=0.8V;;;; 'sensor.voltsDC_35215MB2_0: VOU'=0.898V;;;; 'sensor.celsius_Temp: Outlet_A'=45C;~:59;~:69;; 'sensor.celsius_Temp: Outlet_B'=41C;~:54;~:64;; 'sensor.celsius_Temp: Inlet_B'=44C;~:44;~:64;; 'sensor.celsius_Temp: UADP_0_0'=53C;~:104;~:119;; 'sensor.celsius_Temp: UADP_0_1'=55C;~:104;~:119;; 'sensor.celsius_Temp: UADP_0_2'=55C;~:104;~:119;; 'sensor.celsius_Temp: UADP_0_3'=55C;~:104;~:119;; 'sensor.celsius_Temp: UADP_0_4'=54C;~:104;~:119;; 'sensor.celsius_Temp: UADP_0_5'=53C;~:104;~:119;; 'sensor.celsius_Temp: UADP_0_6'=53C;~:104;~:119;; 'sensor.celsius_Temp: UADP_0_7'=56C;~:104;~:119;; 'sensor.celsius_Temp: UADP_0_8'=55C;~:104;~:119;; 'sensor.voltsDC_PSOC-DB_1: VOUT'=4.999V;;;; 'sensor.voltsDC_PSOC-DB_2: VOUT'=3.301V;;;; 'sensor.voltsDC_PSOC-DB_4: VOUT'=2.5V;;;; 'sensor.voltsDC_PSOC-DB_5: VOUT'=1.699V;;;; 'sensor.voltsDC_PSOC-DB_7: VOUT'=1.499V;;;; 'sensor.voltsDC_PSOC-DB_8: VOUT'=1.296V;;;; 'sensor.voltsDC_PSOC-DB_11: VOU'=0.593V;;;; 'sensor.voltsDC_3570DB1_0: VOUT'=1.788V;;;; 'sensor.voltsDC_3570DB2_0: VOUT'=1.201V;;;; 'sensor.voltsDC_3570DB3_0: VOUT'=1.051V;;;; 'sensor.celsius_Temp: Coretemp'=50C;~:106;~:122;; 'sensor.celsius_Temp: OutletDB'=44C;~:64;~:74;; 'sensor.celsius_Twe1/0/10 Module Temperature Sensor'=45.3C;;;; 'sensor.voltsDC_Twe1/0/10 Supply Voltage Sensor'=3.3V;;;; 'sensor.amperes_Twe1/0/10 Bias Current Sensor'=0.028A;;;; 'sensor.dBm_Twe1/0/10 Transmit Power Sensor'=-2.6dBm;;;; 'sensor.dBm_Twe1/0/10 Receive Power Sensor'=-2.5dBm;;;; 'sensor.celsius_Twe1/0/11 Module Temperature Sensor'=44C;;;; 'sensor.voltsDC_Twe1/0/11 Supply Voltage Sensor'=3.3V;;;; 'sensor.amperes_Twe1/0/11 Bias Current Sensor'=0.029A;;;; 'sensor.dBm_Twe1/0/11 Transmit Power Sensor'=-2.7dBm;;;; 'sensor.dBm_Twe1/0/11 Receive Power Sensor'=-1.9dBm;;;; 'sensor.celsius_Twe1/0/12 Module Temperature Sensor'=47.4C;;;; 'sensor.voltsDC_Twe1/0/12 Supply Voltage Sensor'=3.3V;;;; 'sensor.amperes_Twe1/0/12 Bias Current Sensor'=0.027A;;;; 'sensor.dBm_Twe1/0/12 Transmit Power Sensor'=-2.8dBm;;;; 'sensor.dBm_Twe1/0/12 Receive Power Sensor'=-3dBm;;;; 'sensor.celsius_Twe1/0/14 Module Temperature Sensor'=45.8C;;;; 'sensor.voltsDC_Twe1/0/14 Supply Voltage Sensor'=3.3V;;;; 'sensor.amperes_Twe1/0/14 Bias Current Sensor'=0.029A;;;; 'sensor.dBm_Twe1/0/14 Transmit Power Sensor'=-2.8dBm;;;; 'sensor.dBm_Twe1/0/14 Receive Power Sensor'=-2.5dBm;;;; 'sensor.celsius_Twe1/0/18 Module Temperature Sensor'=46.6C;;;; 'sensor.voltsDC_Twe1/0/18 Supply Voltage Sensor'=3.3V;;;; 'sensor.amperes_Twe1/0/18 Bias Current Sensor'=0.029A;;;; 'sensor.dBm_Twe1/0/18 Transmit Power Sensor'=-2.9dBm;;;; 'sensor.dBm_Twe1/0/18 Receive Power Sensor'=-40dBm;;;; 'sensor.celsius_Twe1/0/20 Module Temperature Sensor'=45.5C;;;; 'sensor.voltsDC_Twe1/0/20 Supply Voltage Sensor'=3.3V;;;; 'sensor.amperes_Twe1/0/20 Bias Current Sensor'=0.0498A;;;; 'sensor.dBm_Twe1/0/20 Transmit Power Sensor'=-2.1dBm;;;; 'sensor.dBm_Twe1/0/20 Receive Power Sensor'=-3.9dBm;;;; 'sensor.celsius_Twe1/0/23 Module Temperature Sensor'=42C;;;; 'sensor.voltsDC_Twe1/0/23 Supply Voltage Sensor'=3.3V;;;; 'sensor.amperes_Twe1/0/23 Bias Current Sensor'=0.0495A;;;; 'sensor.dBm_Twe1/0/23 Transmit Power Sensor'=-1.9dBm;;;; 'sensor.dBm_Twe1/0/23 Receive Power Sensor'=-2.2dBm;;;; 'sensor.celsius_Twe1/0/24 Module Temperature Sensor'=43.3C;;;; 'sensor.voltsDC_Twe1/0/24 Supply Voltage Sensor'=3.3V;;;; 'sensor.amperes_Twe1/0/24 Bias Current Sensor'=0.053A;;;; 'sensor.dBm_Twe1/0/24 Transmit Power Sensor'=-2.1dBm;;;; 'sensor.dBm_Twe1/0/24 Receive Power Sensor'=-1.8dBm;;;; 'sensor.voltsDC_PSOC-MB_0: VOUT'=12.1V;;;; 'sensor.voltsDC_PSOC-MB_1: VOUT'=3.309V;;;; 'sensor.voltsDC_PSOC-MB_2: VOUT'=12.034V;;;; 'sensor.voltsDC_PSOC-MB_3: VOUT'=6.979V;;;; 'sensor.voltsDC_PSOC-MB_4: VOUT'=4.998V;;;; 'sensor.voltsDC_PSOC-MB_5: VOUT'=3.301V;;;; 'sensor.voltsDC_PSOC-MB_7: VOUT'=2.5V;;;; 'sensor.voltsDC_PSOC-MB_8: VOUT'=1.8V;;;; 'sensor.voltsDC_PSOC-MB_9: VOUT'=1.5V;;;; 'sensor.voltsDC_PSOC-MB_10: VOU'=1.2V;;;; 'sensor.voltsDC_3570MB1_0: VOUT'=1V;;;; 'sensor.voltsDC_3570MB2_0: VOUT'=1V;;;; 'sensor.voltsDC_3570MB3_0: VOUT'=1.651V;;;; 'sensor.voltsDC_35215MB1_0: VOU'=0.8V;;;; 'sensor.voltsDC_35215MB2_0: VOU'=0.898V;;;; 'sensor.celsius_Temp: Outlet_A'=44C;~:59;~:69;; 'sensor.celsius_Temp: Outlet_B'=40C;~:54;~:64;; 'sensor.celsius_Temp: Inlet_A'=44C;~:44;~:64;; 'sensor.celsius_Temp: Inlet_B'=43C;~:44;~:64;; 'sensor.celsius_Temp: UADP_0_0'=57C;~:104;~:119;; 'sensor.celsius_Temp: UADP_0_1'=57C;~:104;~:119;; 'sensor.celsius_Temp: UADP_0_2'=57C;~:104;~:119;; 'sensor.celsius_Temp: UADP_0_3'=57C;~:104;~:119;; 'sensor.celsius_Temp: UADP_0_4'=58C;~:104;~:119;; 'sensor.celsius_Temp: UADP_0_5'=57C;~:104;~:119;; 'sensor.celsius_Temp: UADP_0_6'=55C;~:104;~:119;; 'sensor.celsius_Temp: UADP_0_7'=58C;~:104;~:119;; 'sensor.celsius_Temp: UADP_0_8'=57C;~:104;~:119;; 'sensor.voltsDC_PSOC-DB_1: VOUT'=5.001V;;;; 'sensor.voltsDC_PSOC-DB_2: VOUT'=3.302V;;;; 'sensor.voltsDC_PSOC-DB_4: VOUT'=2.5V;;;; 'sensor.voltsDC_PSOC-DB_5: VOUT'=1.699V;;;; 'sensor.voltsDC_PSOC-DB_7: VOUT'=1.5V;;;; 'sensor.voltsDC_PSOC-DB_8: VOUT'=1.299V;;;; 'sensor.voltsDC_PSOC-DB_11: VOU'=0.596V;;;; 'sensor.voltsDC_3570DB1_0: VOUT'=1.788V;;;; 'sensor.voltsDC_3570DB2_0: VOUT'=1.201V;;;; 'sensor.voltsDC_3570DB3_0: VOUT'=1.051V;;;; 'sensor.celsius_Temp: Coretemp'=50C;~:106;~:122;; 'sensor.celsius_Temp: OutletDB'=43C;~:64;~:74;; 'sensor.celsius_Twe2/0/10 Module Temperature Sensor'=44.2C;;;; 'sensor.voltsDC_Twe2/0/10 Supply Voltage Sensor'=3.3V;;;; 'sensor.amperes_Twe2/0/10 Bias Current Sensor'=0.03A;;;; 'sensor.dBm_Twe2/0/10 Transmit Power Sensor'=-2.7dBm;;;; 'sensor.dBm_Twe2/0/10 Receive Power Sensor'=-3.8dBm;;;; 'sensor.celsius_Twe2/0/11 Module Temperature Sensor'=43.1C;;;; 'sensor.voltsDC_Twe2/0/11 Supply Voltage Sensor'=3.3V;;;; 'sensor.amperes_Twe2/0/11 Bias Current Sensor'=0.027A;;;; 'sensor.dBm_Twe2/0/11 Transmit Power Sensor'=-3dBm;;;; 'sensor.dBm_Twe2/0/11 Receive Power Sensor'=-3dBm;;;; 'sensor.celsius_Twe2/0/12 Module Temperature Sensor'=45.5C;;;; 'sensor.voltsDC_Twe2/0/12 Supply Voltage Sensor'=3.3V;;;; 'sensor.amperes_Twe2/0/12 Bias Current Sensor'=0.028A;;;; 'sensor.dBm_Twe2/0/12 Transmit Power Sensor'=-2.7dBm;;;; 'sensor.dBm_Twe2/0/12 Receive Power Sensor'=-3dBm;;;; 'sensor.celsius_Twe2/0/14 Module Temperature Sensor'=44.8C;;;; 'sensor.voltsDC_Twe2/0/14 Supply Voltage Sensor'=3.3V;;;; 'sensor.amperes_Twe2/0/14 Bias Current Sensor'=0.025A;;;; 'sensor.dBm_Twe2/0/14 Transmit Power Sensor'=-2.9dBm;;;; 'sensor.dBm_Twe2/0/14 Receive Power Sensor'=-3.9dBm;;;; 'sensor.celsius_Twe2/0/18 Module Temperature Sensor'=46C;;;; 'sensor.voltsDC_Twe2/0/18 Supply Voltage Sensor'=3.2V;;;; 'sensor.amperes_Twe2/0/18 Bias Current Sensor'=0.041A;;;; 'sensor.dBm_Twe2/0/18 Transmit Power Sensor'=-2.1dBm;;;; 'sensor.dBm_Twe2/0/18 Receive Power Sensor'=-40dBm;;;; 'sensor.celsius_Twe2/0/20 Module Temperature Sensor'=42.2C;;;; 'sensor.voltsDC_Twe2/0/20 Supply Voltage Sensor'=3.3V;;;; 'sensor.amperes_Twe2/0/20 Bias Current Sensor'=0.0522A;;;; 'sensor.dBm_Twe2/0/20 Transmit Power Sensor'=-1.8dBm;;;; 'sensor.dBm_Twe2/0/20 Receive Power Sensor'=-3.2dBm;;;; 'sensor.celsius_Twe2/0/23 Module Temperature Sensor'=43.7C;;;; 'sensor.voltsDC_Twe2/0/23 Supply Voltage Sensor'=3.3V;;;; 'sensor.amperes_Twe2/0/23 Bias Current Sensor'=0.0525A;;;; 'sensor.dBm_Twe2/0/23 Transmit Power Sensor'=-1.8dBm;;;; 'sensor.dBm_Twe2/0/23 Receive Power Sensor'=-2.9dBm;;;; 'sensor.celsius_Twe2/0/24 Module Temperature Sensor'=43.5C;;;; 'sensor.voltsDC_Twe2/0/24 Supply Voltage Sensor'=3.3V;;;; 'sensor.amperes_Twe2/0/24 Bias Current Sensor'=0.0519A;;;; 'sensor.dBm_Twe2/0/24 Transmit Power Sensor'=-2.1dBm;;;; 'sensor.dBm_Twe2/0/24 Receive Power Sensor'=-1.9dBm;;;; 'sensor.celsius_Temp: Inlet_A'=47C;~:44;~:64;; 'count_fan'=28;;;; 'count_module'=2;;;; 'count_psu'=4;;;; 'count_sensor'=160;;;; 'count_temperature'=30;;;;
Environment type: other
Checking fans
fan 'Switch 1 Fan 0/0' status is normal [instance: 8].
fan 'Switch 1 Fan 1/0' status is normal [instance: 11].
fan 'Switch 1 Fan Tray 0' status is normal [instance: 12].
fan 'Switch 1 Fan Tray 1' status is normal [instance: 13].
fan 'Switch 1 Fan 2/0' status is normal [instance: 17].
fan 'Switch 1 Fan 2/1' status is normal [instance: 18].
fan 'Switch 1 Fan 2/2' status is normal [instance: 19].
fan 'Switch 1 Fan 2/3' status is normal [instance: 20].
fan 'Switch 1 Fan 3/0' status is normal [instance: 21].
fan 'Switch 1 Fan 3/1' status is normal [instance: 22].
fan 'Switch 1 Fan 3/2' status is normal [instance: 23].
fan 'Switch 1 Fan 3/3' status is normal [instance: 24].
fan 'Switch 2 Fan 0/0' status is normal [instance: 506].
fan 'Switch 2 Fan 1/0' status is normal [instance: 509].
fan 'Switch 2 Fan Tray 0' status is normal [instance: 510].
fan 'Switch 2 Fan Tray 1' status is normal [instance: 511].
fan 'Switch 2 Fan 2/0' status is normal [instance: 515].
fan 'Switch 2 Fan 2/1' status is normal [instance: 516].
fan 'Switch 2 Fan 2/2' status is normal [instance: 517].
fan 'Switch 2 Fan 2/3' status is normal [instance: 518].
fan 'Switch 2 Fan 3/0' status is normal [instance: 519].
fan 'Switch 2 Fan 3/1' status is normal [instance: 520].
fan 'Switch 2 Fan 3/2' status is normal [instance: 521].
fan 'Switch 2 Fan 3/3' status is normal [instance: 522].
fan 'Cisco Catalyst 9500 Series Fan Tray' status is up [instance: 12]
fan 'Cisco Catalyst 9500 Series Fan Tray' status is up [instance: 13]
fan 'Cisco Catalyst 9500 Series Fan Tray' status is up [instance: 510]
fan 'Cisco Catalyst 9500 Series Fan Tray' status is up [instance: 511]
Checking power supplies
power supply 'Switch 1 Power Supply Module 0' status is normal [instance: 6] [source: ac]
power supply 'Switch 1 Power Supply Module 1' status is normal [instance: 9] [source: ac]
power supply 'Switch 2 Power Supply Module 0' status is normal [instance: 504] [source: ac]
power supply 'Switch 2 Power Supply Module 1' status is normal [instance: 507] [source: ac]
Checking temperatures
temperature 'Switch 1 Slot 1 Temp: Outlet_A' status is normal [instance: 1016] [value: 45 C]
temperature 'Switch 1 Slot 1 Temp: Outlet_B' status is normal [instance: 1017] [value: 41 C]
temperature 'Switch 1 Slot 1 Temp: Inlet_A' status is warning [instance: 1018] [value: 47 C]
temperature 'Switch 1 Slot 1 Temp: Inlet_B' status is normal [instance: 1019] [value: 44 C]
temperature 'Switch 1 Slot 1 Temp: UADP_0_0' status is normal [instance: 1020] [value: 53 C]
temperature 'Switch 1 Slot 1 Temp: UADP_0_1' status is normal [instance: 1021] [value: 55 C]
temperature 'Switch 1 Slot 1 Temp: UADP_0_2' status is normal [instance: 1022] [value: 55 C]
temperature 'Switch 1 Slot 1 Temp: UADP_0_3' status is normal [instance: 1023] [value: 55 C]
temperature 'Switch 1 Slot 1 Temp: UADP_0_4' status is normal [instance: 1024] [value: 54 C]
temperature 'Switch 1 Slot 1 Temp: UADP_0_5' status is normal [instance: 1025] [value: 53 C]
temperature 'Switch 1 Slot 1 Temp: UADP_0_6' status is normal [instance: 1026] [value: 53 C]
temperature 'Switch 1 Slot 1 Temp: UADP_0_7' status is normal [instance: 1027] [value: 56 C]
temperature 'Switch 1 Slot 1 Temp: UADP_0_8' status is normal [instance: 1028] [value: 55 C]
temperature 'Switch 1 Slot 1 Temp: Coretemp' status is normal [instance: 1039] [value: 50 C]
temperature 'Switch 1 Slot 1 Temp: OutletDB' status is normal [instance: 1040] [value: 44 C]
temperature 'Switch 2 Slot 1 Temp: Outlet_A' status is normal [instance: 2016] [value: 44 C]
temperature 'Switch 2 Slot 1 Temp: Outlet_B' status is normal [instance: 2017] [value: 40 C]
temperature 'Switch 2 Slot 1 Temp: Inlet_A' status is normal [instance: 2018] [value: 44 C]
temperature 'Switch 2 Slot 1 Temp: Inlet_B' status is normal [instance: 2019] [value: 43 C]
temperature 'Switch 2 Slot 1 Temp: UADP_0_0' status is normal [instance: 2020] [value: 57 C]
temperature 'Switch 2 Slot 1 Temp: UADP_0_1' status is normal [instance: 2021] [value: 57 C]
temperature 'Switch 2 Slot 1 Temp: UADP_0_2' status is normal [instance: 2022] [value: 57 C]
temperature 'Switch 2 Slot 1 Temp: UADP_0_3' status is normal [instance: 2023] [value: 57 C]
temperature 'Switch 2 Slot 1 Temp: UADP_0_4' status is normal [instance: 2024] [value: 58 C]
temperature 'Switch 2 Slot 1 Temp: UADP_0_5' status is normal [instance: 2025] [value: 57 C]
temperature 'Switch 2 Slot 1 Temp: UADP_0_6' status is normal [instance: 2026] [value: 55 C]
temperature 'Switch 2 Slot 1 Temp: UADP_0_7' status is normal [instance: 2027] [value: 58 C]
temperature 'Switch 2 Slot 1 Temp: UADP_0_8' status is normal [instance: 2028] [value: 57 C]
temperature 'Switch 2 Slot 1 Temp: Coretemp' status is normal [instance: 2039] [value: 50 C]
temperature 'Switch 2 Slot 1 Temp: OutletDB' status is normal [instance: 2040] [value: 43 C]
Checking voltages
Checking modules
module 'Cisco Catalyst 9500 Series Router' status is ok [instance: 1000]
module 'Cisco Catalyst 9500 Series Router' status is ok [instance: 2000]
Checking physicals
Checking sensors
sensor 'PSOC-MB_0: VOUT' status is 'ok' [instance: 1001] [value: 12.067 voltsDC]
sensor 'PSOC-MB_1: VOUT' status is 'ok' [instance: 1002] [value: 3.3 voltsDC]
sensor 'PSOC-MB_2: VOUT' status is 'ok' [instance: 1003] [value: 12.079 voltsDC]
sensor 'PSOC-MB_3: VOUT' status is 'ok' [instance: 1004] [value: 6.967 voltsDC]
sensor 'PSOC-MB_4: VOUT' status is 'ok' [instance: 1005] [value: 5 voltsDC]
sensor 'PSOC-MB_5: VOUT' status is 'ok' [instance: 1006] [value: 3.298 voltsDC]
sensor 'PSOC-MB_7: VOUT' status is 'ok' [instance: 1007] [value: 2.501 voltsDC]
sensor 'PSOC-MB_8: VOUT' status is 'ok' [instance: 1008] [value: 1.8 voltsDC]
sensor 'PSOC-MB_9: VOUT' status is 'ok' [instance: 1009] [value: 1.499 voltsDC]
sensor 'PSOC-MB_10: VOU' status is 'ok' [instance: 1010] [value: 1.2 voltsDC]
sensor '3570MB1_0: VOUT' status is 'ok' [instance: 1011] [value: 1 voltsDC]
sensor '3570MB2_0: VOUT' status is 'ok' [instance: 1012] [value: 1 voltsDC]
sensor '3570MB3_0: VOUT' status is 'ok' [instance: 1013] [value: 1.651 voltsDC]
sensor '35215MB1_0: VOU' status is 'ok' [instance: 1014] [value: 0.8 voltsDC]
sensor '35215MB2_0: VOU' status is 'ok' [instance: 1015] [value: 0.898 voltsDC]
sensor 'Temp: Outlet_A' status is 'ok' [instance: 1016] [value: 45 celsius]
sensor 'Temp: Outlet_B' status is 'ok' [instance: 1017] [value: 41 celsius]
sensor 'Temp: Inlet_A' status is 'ok' [instance: 1018] [value: 47 celsius]
sensor 'Temp: Inlet_B' status is 'ok' [instance: 1019] [value: 44 celsius]
sensor 'Temp: UADP_0_0' status is 'ok' [instance: 1020] [value: 53 celsius]
sensor 'Temp: UADP_0_1' status is 'ok' [instance: 1021] [value: 55 celsius]
sensor 'Temp: UADP_0_2' status is 'ok' [instance: 1022] [value: 55 celsius]
sensor 'Temp: UADP_0_3' status is 'ok' [instance: 1023] [value: 55 celsius]
sensor 'Temp: UADP_0_4' status is 'ok' [instance: 1024] [value: 54 celsius]
sensor 'Temp: UADP_0_5' status is 'ok' [instance: 1025] [value: 53 celsius]
sensor 'Temp: UADP_0_6' status is 'ok' [instance: 1026] [value: 53 celsius]
sensor 'Temp: UADP_0_7' status is 'ok' [instance: 1027] [value: 56 celsius]
sensor 'Temp: UADP_0_8' status is 'ok' [instance: 1028] [value: 55 celsius]
sensor 'PSOC-DB_1: VOUT' status is 'ok' [instance: 1029] [value: 4.999 voltsDC]
sensor 'PSOC-DB_2: VOUT' status is 'ok' [instance: 1030] [value: 3.301 voltsDC]
sensor 'PSOC-DB_4: VOUT' status is 'ok' [instance: 1031] [value: 2.5 voltsDC]
sensor 'PSOC-DB_5: VOUT' status is 'ok' [instance: 1032] [value: 1.699 voltsDC]
sensor 'PSOC-DB_7: VOUT' status is 'ok' [instance: 1033] [value: 1.499 voltsDC]
sensor 'PSOC-DB_8: VOUT' status is 'ok' [instance: 1034] [value: 1.296 voltsDC]
sensor 'PSOC-DB_11: VOU' status is 'ok' [instance: 1035] [value: 0.593 voltsDC]
sensor '3570DB1_0: VOUT' status is 'ok' [instance: 1036] [value: 1.788 voltsDC]
sensor '3570DB2_0: VOUT' status is 'ok' [instance: 1037] [value: 1.201 voltsDC]
sensor '3570DB3_0: VOUT' status is 'ok' [instance: 1038] [value: 1.051 voltsDC]
sensor 'Temp: Coretemp' status is 'ok' [instance: 1039] [value: 50 celsius]
sensor 'Temp: OutletDB' status is 'ok' [instance: 1040] [value: 44 celsius]
sensor 'Twe1/0/10 Module Temperature Sensor' status is 'ok' [instance: 1145] [value: 45.3 celsius]
sensor 'Twe1/0/10 Supply Voltage Sensor' status is 'ok' [instance: 1146] [value: 3.3 voltsDC]
sensor 'Twe1/0/10 Bias Current Sensor' status is 'ok' [instance: 1147] [value: 0.028 amperes]
sensor 'Twe1/0/10 Transmit Power Sensor' status is 'ok' [instance: 1148] [value: -2.6 dBm]
sensor 'Twe1/0/10 Receive Power Sensor' status is 'ok' [instance: 1149] [value: -2.5 dBm]
sensor 'Twe1/0/11 Module Temperature Sensor' status is 'ok' [instance: 1151] [value: 44 celsius]
sensor 'Twe1/0/11 Supply Voltage Sensor' status is 'ok' [instance: 1152] [value: 3.3 voltsDC]
sensor 'Twe1/0/11 Bias Current Sensor' status is 'ok' [instance: 1153] [value: 0.029 amperes]
sensor 'Twe1/0/11 Transmit Power Sensor' status is 'ok' [instance: 1154] [value: -2.7 dBm]
sensor 'Twe1/0/11 Receive Power Sensor' status is 'ok' [instance: 1155] [value: -1.9 dBm]
sensor 'Twe1/0/12 Module Temperature Sensor' status is 'ok' [instance: 1157] [value: 47.4 celsius]
sensor 'Twe1/0/12 Supply Voltage Sensor' status is 'ok' [instance: 1158] [value: 3.3 voltsDC]
sensor 'Twe1/0/12 Bias Current Sensor' status is 'ok' [instance: 1159] [value: 0.027 amperes]
sensor 'Twe1/0/12 Transmit Power Sensor' status is 'ok' [instance: 1160] [value: -2.8 dBm]
sensor 'Twe1/0/12 Receive Power Sensor' status is 'ok' [instance: 1161] [value: -3 dBm]
sensor 'Twe1/0/14 Module Temperature Sensor' status is 'ok' [instance: 1169] [value: 45.8 celsius]
sensor 'Twe1/0/14 Supply Voltage Sensor' status is 'ok' [instance: 1170] [value: 3.3 voltsDC]
sensor 'Twe1/0/14 Bias Current Sensor' status is 'ok' [instance: 1171] [value: 0.029 amperes]
sensor 'Twe1/0/14 Transmit Power Sensor' status is 'ok' [instance: 1172] [value: -2.8 dBm]
sensor 'Twe1/0/14 Receive Power Sensor' status is 'ok' [instance: 1173] [value: -2.5 dBm]
sensor 'Twe1/0/18 Module Temperature Sensor' status is 'ok' [instance: 1193] [value: 46.6 celsius]
sensor 'Twe1/0/18 Supply Voltage Sensor' status is 'ok' [instance: 1194] [value: 3.3 voltsDC]
sensor 'Twe1/0/18 Bias Current Sensor' status is 'ok' [instance: 1195] [value: 0.029 amperes]
sensor 'Twe1/0/18 Transmit Power Sensor' status is 'ok' [instance: 1196] [value: -2.9 dBm]
sensor 'Twe1/0/18 Receive Power Sensor' status is 'ok' [instance: 1197] [value: -40 dBm]
sensor 'Twe1/0/20 Module Temperature Sensor' status is 'ok' [instance: 1205] [value: 45.5 celsius]
sensor 'Twe1/0/20 Supply Voltage Sensor' status is 'ok' [instance: 1206] [value: 3.3 voltsDC]
sensor 'Twe1/0/20 Bias Current Sensor' status is 'ok' [instance: 1207] [value: 0.0498 amperes]
sensor 'Twe1/0/20 Transmit Power Sensor' status is 'ok' [instance: 1208] [value: -2.1 dBm]
sensor 'Twe1/0/20 Receive Power Sensor' status is 'ok' [instance: 1209] [value: -3.9 dBm]
sensor 'Twe1/0/23 Module Temperature Sensor' status is 'ok' [instance: 1223] [value: 42 celsius]
sensor 'Twe1/0/23 Supply Voltage Sensor' status is 'ok' [instance: 1224] [value: 3.3 voltsDC]
sensor 'Twe1/0/23 Bias Current Sensor' status is 'ok' [instance: 1225] [value: 0.0495 amperes]
sensor 'Twe1/0/23 Transmit Power Sensor' status is 'ok' [instance: 1226] [value: -1.9 dBm]
sensor 'Twe1/0/23 Receive Power Sensor' status is 'ok' [instance: 1227] [value: -2.2 dBm]
sensor 'Twe1/0/24 Module Temperature Sensor' status is 'ok' [instance: 1229] [value: 43.3 celsius]
sensor 'Twe1/0/24 Supply Voltage Sensor' status is 'ok' [instance: 1230] [value: 3.3 voltsDC]
sensor 'Twe1/0/24 Bias Current Sensor' status is 'ok' [instance: 1231] [value: 0.053 amperes]
sensor 'Twe1/0/24 Transmit Power Sensor' status is 'ok' [instance: 1232] [value: -2.1 dBm]
sensor 'Twe1/0/24 Receive Power Sensor' status is 'ok' [instance: 1233] [value: -1.8 dBm]
sensor 'PSOC-MB_0: VOUT' status is 'ok' [instance: 2001] [value: 12.1 voltsDC]
sensor 'PSOC-MB_1: VOUT' status is 'ok' [instance: 2002] [value: 3.309 voltsDC]
sensor 'PSOC-MB_2: VOUT' status is 'ok' [instance: 2003] [value: 12.034 voltsDC]
sensor 'PSOC-MB_3: VOUT' status is 'ok' [instance: 2004] [value: 6.979 voltsDC]
sensor 'PSOC-MB_4: VOUT' status is 'ok' [instance: 2005] [value: 4.998 voltsDC]
sensor 'PSOC-MB_5: VOUT' status is 'ok' [instance: 2006] [value: 3.301 voltsDC]
sensor 'PSOC-MB_7: VOUT' status is 'ok' [instance: 2007] [value: 2.5 voltsDC]
sensor 'PSOC-MB_8: VOUT' status is 'ok' [instance: 2008] [value: 1.8 voltsDC]
sensor 'PSOC-MB_9: VOUT' status is 'ok' [instance: 2009] [value: 1.5 voltsDC]
sensor 'PSOC-MB_10: VOU' status is 'ok' [instance: 2010] [value: 1.2 voltsDC]
sensor '3570MB1_0: VOUT' status is 'ok' [instance: 2011] [value: 1 voltsDC]
sensor '3570MB2_0: VOUT' status is 'ok' [instance: 2012] [value: 1 voltsDC]
sensor '3570MB3_0: VOUT' status is 'ok' [instance: 2013] [value: 1.651 voltsDC]
sensor '35215MB1_0: VOU' status is 'ok' [instance: 2014] [value: 0.8 voltsDC]
sensor '35215MB2_0: VOU' status is 'ok' [instance: 2015] [value: 0.898 voltsDC]
sensor 'Temp: Outlet_A' status is 'ok' [instance: 2016] [value: 44 celsius]
sensor 'Temp: Outlet_B' status is 'ok' [instance: 2017] [value: 40 celsius]
sensor 'Temp: Inlet_A' status is 'ok' [instance: 2018] [value: 44 celsius]
sensor 'Temp: Inlet_B' status is 'ok' [instance: 2019] [value: 43 celsius]
sensor 'Temp: UADP_0_0' status is 'ok' [instance: 2020] [value: 57 celsius]
sensor 'Temp: UADP_0_1' status is 'ok' [instance: 2021] [value: 57 celsius]
sensor 'Temp: UADP_0_2' status is 'ok' [instance: 2022] [value: 57 celsius]
sensor 'Temp: UADP_0_3' status is 'ok' [instance: 2023] [value: 57 celsius]
sensor 'Temp: UADP_0_4' status is 'ok' [instance: 2024] [value: 58 celsius]
sensor 'Temp: UADP_0_5' status is 'ok' [instance: 2025] [value: 57 celsius]
sensor 'Temp: UADP_0_6' status is 'ok' [instance: 2026] [value: 55 celsius]
sensor 'Temp: UADP_0_7' status is 'ok' [instance: 2027] [value: 58 celsius]
sensor 'Temp: UADP_0_8' status is 'ok' [instance: 2028] [value: 57 celsius]
sensor 'PSOC-DB_1: VOUT' status is 'ok' [instance: 2029] [value: 5.001 voltsDC]
sensor 'PSOC-DB_2: VOUT' status is 'ok' [instance: 2030] [value: 3.302 voltsDC]
sensor 'PSOC-DB_4: VOUT' status is 'ok' [instance: 2031] [value: 2.5 voltsDC]
sensor 'PSOC-DB_5: VOUT' status is 'ok' [instance: 2032] [value: 1.699 voltsDC]
sensor 'PSOC-DB_7: VOUT' status is 'ok' [instance: 2033] [value: 1.5 voltsDC]
sensor 'PSOC-DB_8: VOUT' status is 'ok' [instance: 2034] [value: 1.299 voltsDC]
sensor 'PSOC-DB_11: VOU' status is 'ok' [instance: 2035] [value: 0.596 voltsDC]
sensor '3570DB1_0: VOUT' status is 'ok' [instance: 2036] [value: 1.788 voltsDC]
sensor '3570DB2_0: VOUT' status is 'ok' [instance: 2037] [value: 1.201 voltsDC]
sensor '3570DB3_0: VOUT' status is 'ok' [instance: 2038] [value: 1.051 voltsDC]
sensor 'Temp: Coretemp' status is 'ok' [instance: 2039] [value: 50 celsius]
sensor 'Temp: OutletDB' status is 'ok' [instance: 2040] [value: 43 celsius]
sensor 'Twe2/0/10 Module Temperature Sensor' status is 'ok' [instance: 2145] [value: 44.2 celsius]
sensor 'Twe2/0/10 Supply Voltage Sensor' status is 'ok' [instance: 2146] [value: 3.3 voltsDC]
sensor 'Twe2/0/10 Bias Current Sensor' status is 'ok' [instance: 2147] [value: 0.03 amperes]
sensor 'Twe2/0/10 Transmit Power Sensor' status is 'ok' [instance: 2148] [value: -2.7 dBm]
sensor 'Twe2/0/10 Receive Power Sensor' status is 'ok' [instance: 2149] [value: -3.8 dBm]
sensor 'Twe2/0/11 Module Temperature Sensor' status is 'ok' [instance: 2151] [value: 43.1 celsius]
sensor 'Twe2/0/11 Supply Voltage Sensor' status is 'ok' [instance: 2152] [value: 3.3 voltsDC]
sensor 'Twe2/0/11 Bias Current Sensor' status is 'ok' [instance: 2153] [value: 0.027 amperes]
sensor 'Twe2/0/11 Transmit Power Sensor' status is 'ok' [instance: 2154] [value: -3 dBm]
sensor 'Twe2/0/11 Receive Power Sensor' status is 'ok' [instance: 2155] [value: -3 dBm]
sensor 'Twe2/0/12 Module Temperature Sensor' status is 'ok' [instance: 2157] [value: 45.5 celsius]
sensor 'Twe2/0/12 Supply Voltage Sensor' status is 'ok' [instance: 2158] [value: 3.3 voltsDC]
sensor 'Twe2/0/12 Bias Current Sensor' status is 'ok' [instance: 2159] [value: 0.028 amperes]
sensor 'Twe2/0/12 Transmit Power Sensor' status is 'ok' [instance: 2160] [value: -2.7 dBm]
sensor 'Twe2/0/12 Receive Power Sensor' status is 'ok' [instance: 2161] [value: -3 dBm]
sensor 'Twe2/0/14 Module Temperature Sensor' status is 'ok' [instance: 2169] [value: 44.8 celsius]
sensor 'Twe2/0/14 Supply Voltage Sensor' status is 'ok' [instance: 2170] [value: 3.3 voltsDC]
sensor 'Twe2/0/14 Bias Current Sensor' status is 'ok' [instance: 2171] [value: 0.025 amperes]
sensor 'Twe2/0/14 Transmit Power Sensor' status is 'ok' [instance: 2172] [value: -2.9 dBm]
sensor 'Twe2/0/14 Receive Power Sensor' status is 'ok' [instance: 2173] [value: -3.9 dBm]
sensor 'Twe2/0/18 Module Temperature Sensor' status is 'ok' [instance: 2193] [value: 46 celsius]
sensor 'Twe2/0/18 Supply Voltage Sensor' status is 'ok' [instance: 2194] [value: 3.2 voltsDC]
sensor 'Twe2/0/18 Bias Current Sensor' status is 'ok' [instance: 2195] [value: 0.041 amperes]
sensor 'Twe2/0/18 Transmit Power Sensor' status is 'ok' [instance: 2196] [value: -2.1 dBm]
sensor 'Twe2/0/18 Receive Power Sensor' status is 'ok' [instance: 2197] [value: -40 dBm]
sensor 'Twe2/0/20 Module Temperature Sensor' status is 'ok' [instance: 2205] [value: 42.2 celsius]
sensor 'Twe2/0/20 Supply Voltage Sensor' status is 'ok' [instance: 2206] [value: 3.3 voltsDC]
sensor 'Twe2/0/20 Bias Current Sensor' status is 'ok' [instance: 2207] [value: 0.0522 amperes]
sensor 'Twe2/0/20 Transmit Power Sensor' status is 'ok' [instance: 2208] [value: -1.8 dBm]
sensor 'Twe2/0/20 Receive Power Sensor' status is 'ok' [instance: 2209] [value: -3.2 dBm]
sensor 'Twe2/0/23 Module Temperature Sensor' status is 'ok' [instance: 2223] [value: 43.7 celsius]
sensor 'Twe2/0/23 Supply Voltage Sensor' status is 'ok' [instance: 2224] [value: 3.3 voltsDC]
sensor 'Twe2/0/23 Bias Current Sensor' status is 'ok' [instance: 2225] [value: 0.0525 amperes]
sensor 'Twe2/0/23 Transmit Power Sensor' status is 'ok' [instance: 2226] [value: -1.8 dBm]
sensor 'Twe2/0/23 Receive Power Sensor' status is 'ok' [instance: 2227] [value: -2.9 dBm]
sensor 'Twe2/0/24 Module Temperature Sensor' status is 'ok' [instance: 2229] [value: 43.5 celsius]
sensor 'Twe2/0/24 Supply Voltage Sensor' status is 'ok' [instance: 2230] [value: 3.3 voltsDC]
sensor 'Twe2/0/24 Bias Current Sensor' status is 'ok' [instance: 2231] [value: 0.0519 amperes]
sensor 'Twe2/0/24 Transmit Power Sensor' status is 'ok' [instance: 2232] [value: -2.1 dBm]
sensor 'Twe2/0/24 Receive Power Sensor' status is 'ok' [instance: 2233] [value: -1.9 dBm]
garnier-quentin commented 1 year ago

For the following error Temperature 'Switch 1 Slot 1 Temp: Inlet_A' status is warning it's the status provided by cisco: .1.3.6.1.4.1.9.9.13.1.3.1.6 (ciscoEnvMonTemperatureState)

And for the error Sensor 'Temp: Inlet_A/1018' i don't see the perfdata

joschi99 commented 1 year ago

Hi @garnier-quentin, you are completly right. I have not seen/checked the status. Sorry

joschi99 commented 4 weeks ago

I would like to reopen this case because we have still problems with wrong alarms for this kind of Temperatur Sensors and the problem is not the OID .1.3.6.1.4.1.9.9.13.1.3.1.6 (ciscoEnvMonTemperatureState):

WARNING: Sensor 'Switch 1 - C9200L-48P-4X - Temp Inlet Sensor 0/1010' is 30 C | 'temp_Switch 1 - Inlet Temp Sensor, GREEN '=30C;;~:56;; 'temp_Switch 1 - Outlet Temp Sensor, GREEN '=40C;;~:125;; 'temp_Switch 1 - HotSpot Temp Sensor, GREEN '=51C;;~:125;; 'sensor.celsius_Switch 1 - C9200L-48P-4X - Temp Outlet Sensor 1'=40C;;-9:124;; 'sensor.celsius_Switch 1 - C9200L-48P-4X - Temp Hotspot Sensor 2'=51C;;-9:124;; 'sensor.celsius_Switch 1 - C9200L-48P-4X - Temp Inlet Sensor 0'=30C;32:45;-9:55;; 'count_fan'=4;;;; 'count_module'=1;;;; 'count_psu'=1;;;; 'count_sensor'=3;;;; 'count_temperature'=3;;;;
.1.3.6.1.2.1.47.1.1.1.1.2.1010 = Switch 1 - C9200L-48P-4X - Temp Inlet Sensor 0
.1.3.6.1.4.1.9.9.13.1.3.1.2.1010 = Switch 1 - Inlet Temp Sensor, GREEN
.1.3.6.1.4.1.9.9.13.1.3.1.3.1010 = 30
.1.3.6.1.4.1.9.9.13.1.3.1.4.1010 = 56
.1.3.6.1.4.1.9.9.13.1.3.1.5.1010 = 0
.1.3.6.1.4.1.9.9.13.1.3.1.6.1010 = 1
.1.3.6.1.4.1.9.9.13.1.3.1.7.1010 = 30
.1.3.6.1.4.1.9.9.91.1.1.1.1.1.1010 = 8
.1.3.6.1.4.1.9.9.91.1.1.1.1.2.1010 = 9
.1.3.6.1.4.1.9.9.91.1.1.1.1.3.1010 = 0
.1.3.6.1.4.1.9.9.91.1.1.1.1.4.1010 = 30
.1.3.6.1.4.1.9.9.91.1.1.1.1.5.1010 = 1
.1.3.6.1.4.1.9.9.91.1.2.1.1.2.1010.1 = 20
.1.3.6.1.4.1.9.9.91.1.2.1.1.2.1010.2 = 10
.1.3.6.1.4.1.9.9.91.1.2.1.1.2.1010.3 = 10
.1.3.6.1.4.1.9.9.91.1.2.1.1.2.1010.4 = 20
.1.3.6.1.4.1.9.9.91.1.2.1.1.3.1010.1 = 4
.1.3.6.1.4.1.9.9.91.1.2.1.1.3.1010.2 = 4
.1.3.6.1.4.1.9.9.91.1.2.1.1.3.1010.3 = 2
.1.3.6.1.4.1.9.9.91.1.2.1.1.3.1010.4 = 2
.1.3.6.1.4.1.9.9.91.1.2.1.1.4.1010.1 = 56
.1.3.6.1.4.1.9.9.91.1.2.1.1.4.1010.2 = 46
.1.3.6.1.4.1.9.9.91.1.2.1.1.4.1010.3 = 31
.1.3.6.1.4.1.9.9.91.1.2.1.1.4.1010.4 = -10
temperature 'Switch 1 - Inlet Temp Sensor, GREEN ' status is normal [instance: 1010] [value: 30 C]
sensor 'Switch 1 - C9200L-48P-4X - Temp Inlet Sensor 0' status is 'ok' [instance: 1010] [value: 30 celsius]
.1.3.6.1.4.1.9.9.91.1.1.1.1.7.1010 = 600

As you can see OID .1.3.6.1.4.1.9.9.13.1.3.1.6 returns value 1 that means "normal status": image

We have a lot of similare cases and actually we need to override temperature thresholds manually for this problem.