LDWin Ver 2.0 not wotking with Dell 5548 PowereConnect #1

Closed kenmullins closed 9 years ago

kenmullins commented 10 years ago

When I use LDWin ver 2.0 with a Dell 5548 PowereConnect it passes through the switch and goes to the next switch upstream. O/S Win 7 pro

chall32 commented 10 years ago

According to http://www.dell.com/us/business/p/powerconnect-5448/pd it looks like the Dell 5548 supports LLDP. Is LLDP enabled on the 5548 you are testing against?

kenmullins commented 10 years ago

Yes, the 5548 is configured to support LLDP and it does work with haneWIN LLDP Agent 1.4.9; but not LDWin. I prefer LDWin

Thanks

Ken Mullins

From: Chris Hall [mailto:notifications@github.com] Sent: Wednesday, April 09, 2014 11:32 AM To: chall32/LDWin Cc: kenmullins Subject: Re: [LDWin] LDWin Ver 2.0 not wotking with Dell 5548 PowereConnect (#1)

According to http://www.dell.com/us/business/p/powerconnect-5448/pd it looks like the Dell 5548 supports LLDP. Is LLDP enabled on the 5548 you are testing against? — Reply to this email directly or view it on GitHub https://github.com/chall32/LDWin/issues/1#issuecomment-39985631 . https://github.com/notifications/beacon/7225279__eyJzY29wZSI6Ik5ld3NpZXM6QmVhY29uIiwiZXhwaXJlcyI6MTcxMjY4MDMxNSwiZGF0YSI6eyJpZCI6Mjk1MTc0Nzh9fQ==--2791c3e9fdce3597c917bb35e34e324899c34317.gif

chall32 commented 10 years ago

Hey Ken, OK, no problem. Please can you have a look this https://github.com/chall32/LDWin/wiki/What-To-Do-If-LDWin-Captures-No-Data and letting me have the returned data? Thanks!

chall32 commented 10 years ago

Hey Ken,

I've tracked down the LLDP detection problem and I've just released a new version, v2.1 that I hope will work for you.

Please feel free to go ahead and test again using LDWin v2.1 and let me know if it works OK for you.

As always, feedback is much appreciated!

kenmullins commented 10 years ago

It worked, thanks

Ken Mullins 972-708-7414 Network Administrator Global Technology & Information Services SIL International

kenmullins commented 10 years ago

Chris,

I have noticed what appears as odd to me. if you keep clicking on Get Link Data" it will cycle through the neighbor switches. 1st time -- HUNT7000-182 Gi5/0/19 <-- this the Core switch, not the first switch 2nd time --HUNT6248-179 1/0/43 <-- this is a neighbor switch, using this port to connect to Hunt5548-34 3rd time -- same as above 4th time -- same as above 5th time -- MullinsK1102 Intel(R) 82577LM Gigabit Network Connection <-- my Workstation 6th time --HUNT6248-179 1/0/43 <-- this is a neighbor switch, 7th time -- same as above 8th time -- MullinsK1102 Intel(R) 82577LM Gigabit Network Connection <-- my Workstation 9th time -- same as above 10th time HUNT5548-34 gigabitethernet1/0/16 <-- the correct switch and port

chall32 commented 10 years ago

Strange. Could it be that you have OpenFlow http://groups.geni.net/geni/wiki/OpenFlowDiscoveryProtocol#OpenFlowDiscoveryProtocolOFDP enabled on the network?