Closed micko247 closed 4 years ago
Append [SG] to the name, since it’s reporting in SG BF requires [SG] in the name.
Thanks cswelin, do you mean the name of the spindle? Mine are Red and Blue. Do you have a link that describes this? Thanks
@micko247
Correct, in the ispindel configuration, so you’d namw yours Red[SG] and Blue[SG]. I’ve never had luck putting it as a prefix (would still report 1.004), only suffix. Here’s the doc explanation it https://docs.brewfather.app/integrations/ispindel
Great thanks. Unfortunately I can’t access configuration. I may try re-loading the firmware. Thanks
You should be able to reset to config mode by shorting the two holes on the top of the PCB a couple times In row. (on the part that sticks out)
I don’t think the v3.2 has this. The reset on the wemos does work, the light starts blinking, and it establishes an access point I can connect to on my computer. But it doesn’t connect successfully. I’ve tried several times on both units.
Right,
Does it connect to the access point but not load the captive portal? if so, try going to 192.168.4.1
in the browser
Correct, and I’ve tried 192.168.4.1
Ahhh, now I see the bit about Plato & SG. I’d missed that bit. Cheers
Specific issue fixed, for some reason Chrome went offline.
Hi, I have recently built two units (v3.2) & both are logging. (I actually had a number of issues, have built 10, especially with the temp logging, but I’ll leave that for another post). I believe I got something wrong with the calibration as the SG stays at 1.004 regardless of the tilt. I use brewfather to log via http. I had no problems accessing configuration until now after they’ve started logging. I cannot access the config even though the wemos does rest and try to open an access point but it logs out.
Thanks in advance, Mick